Installation/Mounting
CAUTION: Not For Continuous Duty, Intermittent Duty Only
CAUTION: Installation Notes: To avoid the risk of fire. Be sure that the area
where pump is installed is isolated from gas, fuel tanks, electrical wiring looms
or flammable substances. Failure to do so may cause injury or death.
CAUTION: Installation Notes: To avoid the risk of fire. Do not install this
product if visible damaged. If damage exposes electrical contacts, electrical
sparks could ignite fuel fumes. Failure to do so may cause injury or death.
1:
Select pump location. Pump must be installed in a dry, ventilated area.
HORIZONTAL
2:
For a pump only installation, connect fittings supplied with the pump to the
system plumbing. Use 3/8" (9mm) I.D. flexible hose (preferably braided or
reinforced) to reduce vibration through the plumbing system. Use hose clamps
on the slip on barb hose connectors. For a pump and faucet utilize included
tubing and John Guest (type) fittings.
3:
Fasten pump to a flat surface. If mounting vertically; install with pumphead
down. Do not over tighten screws to allow rubber mounts to absorb vibration.
TYPICAL
NOTE: Do Not Submerge
VERTICAL
7