Maintenance; Troubleshooting - Urrea SOLT1020-BV Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Aluminum Welding Parameter
0.6
1.0~1.6
0~1.0
25~40
1.0
1.0~1.6
0~1.6
40~60
1.5
1.0~1.6
0~1.6
60~90
2.5
1.6~2.4 1.6~2.4 80~120
3.0
1.6~2.4 1.6~2.4 100~160
4.0
2.4
1.6~2.4 130~200 10~15
5.0
2.4~3.2 2.4~3.2 150~250 10~15
6.0
2.4~3.2 2.4~3.2 200~280 10~15
8.0
3.2~4.0 3.2~4.0 200~300 12~18
SPACING SHAPES
( A )
( C )

MAINTENANCE

WARNING: Make sure the Power Switch of
the Plasma Cutter is in its "OFF" position and
that the tool is unplugged from the electrical
outlet before performing any inspection, main-
tenance, or cleaning procedures.
1. Before each use, inspect the general condi-
tion of the Air Plasma Cutter. Check for loose
cable connections, misalignment or binding
of the fan, cracked or broken parts, damaged
electrical wiring, and any other condition that
may affect its safe operation. If abnormal noise
or vibration occurs, have the problem corrected
before further use. Do not use damaged equip-
ment.
2. Periodically recheck all nuts, bolts, and screws
for tightness.
18
4~5
1
a, b
4~7
1
a, b
6~9
1
b
6~9
1
b
7~10
1~2
b, c
2~3
c, d
2~3
c, d
3~4
c, d
4~5
d
( B )
( D )
3. Periodically blow the dust from the cooling
vents with compressed air.
4. Verify that the cooling fan is operational be-
fore cutting.
5. If the unit repeatedly shuts down from ther-
mal overload, stop all use. Have the Air Plasma
Cutter inspected and repaired by a qualified
service technician.
6. Store the welder and accessories in a clean
and dry location.
7. Periodically disassemble and clean the Torch
Head components with steel wool. Replace
burnt, cracked, distorted, or coated compo-
nents.
8. To gain access to the internal components of
the unit, remove screws from Main Body Cover.
The home user is strongly advised not to remove
the tool covers and not to attempt any elec-
tronic repairs. Any repairs must be completed
by a qualified technician. Opening the tool will
void any warranties, and may result in damage
to equipment or possible personal injury. Don't
do it.
9. On a daily basis check for any of the following
problems: If any are found, take the tool to a
qualified repair technician.
a. Abnormal vibration, sound or smell.
b. Abnormal heating at any cable connection.
c. Then fan does not work properly.
d. Any switch or control does not work prop-
erly.
e. Any damage to cables.

TROUBLESHOOTING

Be CERTAIN to shut off the TIG Welder, and dis-
connect it from power and air before adjusting,
cleaning, or repairing the unit. A technician
should discharge all capacitors before perform-
ing and internal procedures.
TOOL WILL NOT START
No power at outlet. Check power at outlet.
Cord not connected. Check that cord is plugged
in.
Line voltage incorrect. Make sure the welder is
plugged into a 230V electrical outlet.
NO WELD OUTPUT WITH READY LIGHT ON
Weld cable loose. Tighten weld cable connec-
tion at welder.
Bad work clamp to workpiece connection. Make
sure the area where the clamp is attached is
clean, exposed metal; free of dirt, paint and oil.

Publicidad

Tabla de contenido
loading

Tabla de contenido