This manual has been prepared to acquaint you with the operation and maintenance of this product. Study the
information provided carefully to avoid problems associated with improper application or maintenance. Upon receipt
of your generator, verify that it is complete and in good condition.
The generator is comprised of a 4 stroke, air-cooled engine directly coupled to a 2 pole alternator producing either
125VAC or 125/250VAC depending on model. The no-load speed is approximately 3750rpm with the speed under
load going to approximately 3600rpm thus producing a frequency of 60Hz.
INITIAL INSPECTION
Upon receiving your generator set, inspect the product to make
sure it is complete and in good condition. Handle with care and
place in a suitable site for storage or operation.
GROUND CONNECTION
The generator can be grounded to earth to reduce the chance
of electrical shock. To do this you will need a grounding rod
and an appropriately sized copper ground wire. Drive the
ground rod into the earth, connect one end of the copper wire
to the rod and connect the other end to the external ground
connection on the generator set. This is a general explanation,
consult National and Local electrical codes to ensure
compliance.
GENERATOR NEUTRAL BOND
There is a permanent conductor between the generator
(stator winding) and the frame.

BEFORE START-UP

ENGINE FUEL
Use Unleaded Gasoline with minimum Octane 86. Check the
fuel gauge and add as necessary.
CAUTION:
SLOWLY ADD UNLEADED GASOLINE TO FUEL
TANK
DO NOT OVERFILL TANK
DO NOT FILL ABOVE TOP OF FUEL SCREEN.
ENGINE OIL
The engine manual or other information provided by the engine
manufacturer supersedes data provided here. Proper oil grade
varies with climate. The grade listed in the table is typically a
good grade but consult the engine manual to verify proper
grade. The oil fill ports are located on both sides of the engine.
The gray filler cap has an integral dipstick. Add the proper
amount of oil and check the level using the dipstick. NOTE:
The dipstick should be placed into the filler opening but not
screwed in to check the level.
English

OPERATION

GENERAL INFORMATION

ENGINE
Subaru SP170
POSITIONING
Place the generator set on a flat and solid surface to
prevent it from sinking.
Keep fuel, oil or other explosives at a safe distance from
the generator set.
Select a site that is well ventilated and protected from the
weather.
Place the generator set safely away from people and
animals.
CAUTION: TILTING CAN CAUSE FUEL SPILLAGE
Check the engine oil before each use. Never operate the
generator set with insufficient oil.
GENERATOR SET OVERLOAD
Do not exceed the rated load of the generator set when
operating continuously. Before connecting items to the
generator set, determine the total electrical requirements of the
products to be connected. The requirement of each item is
generally given on the manufacturer's nameplate. Following is
a list of commonly used items and typical requirements. Use
this list as a guideline only if no other data is available.
9
HP
Oil Capacity
Grade
5.7
0.63 qt (0.6 l) API SJ SAE 10W-30
OPERATION
0069439