Water Supply And Drain Connections; Start-Up Procedure - Hoshizaki FM-480AKE-HC Manual De Instalación

Máquina de cubitos modular
Ocultar thumbs Ver también para FM-480AKE-HC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27

7. WATER SUPPLY AND DRAIN CONNECTIONS

* The connections to the mains water supply must be made in
accordance with the countries' current requirements of the Water
Supply or Water Fittings Regulations.
* Water supply pressure should be minimum 0.05 MPa (0.5 bar) and
maximum 0.78 MPa (8 bar). If the pressure exceeds 0.78 MPa (8
bar), use a proper pressure reducing valve. Do NOT throttle back
the supply tap.
* A plumbing permit and services of a licensed plumber may be
required in some areas.
* The icemaker drain is gravity flow, so ensure drain pipe has an
adequate pitch or fall.
* Water should drain into an open trap.
* Drain lines should not be piped directly to the sewer system. A
vertical air gap of a minimum of 5 cm should be between the end
of the drain pipes from the icemaker and storage bin and the floor
drain.
* Water supply connection is intended to be made by means of a
pipe, not a hose set.

8. START-UP PROCEDURE

1) Check that the power supply cord is disconnected.
2) Move the operation switch on the operation panel to the "ON" position.
3) Open the water supply tap.
4) Connect the power supply and energise.
5) The display will illuminate in the "ICE" mode.
6) The following should occur in sequence:
a) Water reservoir will fill.
b) Gear motor will start.
c) Compressor will start.
Check the conditions and quality of the ice production.
Do not use ice produced in the trial run. It might be contaminated with foreign matter in the water circuit. Discard or flush down
the drain.
Clean the storage bin before use (see "III. 1. CLEANING" in instruction manual).
WARNING
Connect to potable water supply only.
Drain Valve
Separate piping to approved
drain. Leave a 5cm vertical
air gap between the end of
each pipe and the drain.
HYGIENE
5
Water Supply
Inlet G3/4
Water Supply Line
Shut-off Valve
Floor
Drain
Operation Panel
Ice Button
Display
Maintenance Button
(service use only)
ENGLISH
Drain Outlet
R3/4
Bin Drain Outlet
3/4 FPT
5cm air gap
Stop Button
Operation Switch

Publicidad