Electrical Connections; Installation Instructions; Water Supply And Drain Connections - Hoshizaki FM-1000ASFE3 Manual De Instrucciones

Ocultar thumbs Ver también para FM-1000ASFE3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
IMPORTANT
. This booklet is an integral and essential
part of the product and should be kept
and preserved by the user. Please read
carefully the guidelines and warnings
contained herein as they are intended
t o p r o v i d e t h e u s e r w i t h e s s e n t i a l
information for the continued safe use and
maintenance of the product. In addition,
it provides GUIDANCE ONLY to the user
on the correct services and site location of
the icemaker. Please preserve this booklet
for any further consultation that may be
necessary.
2. This is a commercial icemaker, and should
be destined only to be used for the purpose
for which it has been expressly designed
and attached to a suitable Storage Bin
as specified by Hoshizaki. Any other
use should be considered improper and
therefore dangerous. The manufacturer
will not be held liable or responsible for any
damage caused by improper, incorrect and
unreasonable use.
I. INSTALLATION INSTRUCTIONS
WARNING
The ins ta lla tion m us t be c a r r ie d out
by qualified personnel, in accordance
with current regulations, according to the
manufacturer's instructions.
1. LOCATION
IMPORTANT
. T h i s i c e m a k e r i s n o t i n t e n d e d f o r
outdoor use. Normal operating ambient
temperature should be within 5°C to 40°
C. Normal operating water temperature
should be within 5°C to 35°C. Operation of
the icemaker, for extended periods, outside
of these normal temperature ranges may
affect production capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
4. Allow 5 cm clearance at rear and sides
for proper air circulation and ease of
maintenance and/or service should they be
All manuals and user guides at all-guides.com

required. Allow 60 cm clearance on top to
allow for removal of the Auger.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. D o n o t p l a c e a n y t h i n g o n t o p o f t h e
icemaker or in front of the Louver.

2. ELECTRICAL CONNECTIONS

WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets
t h e n a t i o n a l a n d l o c a l e l e c t r i c a l c o d e
requirements. To prevent possible severe
electrical shock to individuals or extensive
damage to equipment, install a proper earth
wire to the icemaker.
* This icemaker must have a separate power
supply or receptacle of 3N~400V (Three-phase
star, four-wire; earthed neutral).
* When the power supply cord is connected, it
must have a capacity of not less than 0A.
* The fixed wiring must incorporate a means for
disconnection from the supply having a contact
separation of at least 3 mm in all poles.
* Usually an electrical permit and services of a
licensed electrician are required.
* If the supply cord is damaged, it must be
replaced by the manufacturer or its service agent
of a similarly qualified person in order to avoid a
hazard.
* In accordance with the requirement of the IEC
standard, the maximum permissible system
impedance (Zmax) at the interface point of the
power supply to be connected with this icemaker
must be 0.0225+j0.0225 ohm. Determine
in consultation with the supply authority, if
necessary, that the icemaker is connected only to
a supply of 0.0225+j0.0225 ohm or less.
3. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Only potable water should be used for the
icemaker.
ENGLISH