Electrical Installation - Speck pumps Badu Jet super-sport II Manual De Instalación

Sistema de nado contra corriente
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Final Assembly - continued
Figure 15
Installation of Light Cover

Electrical Installation

WARNING: The wiring of the pool motor and control box should be done by a licensed electrician in accordance with all
local, state, and federal codes. Be certain that the motor frame and control box are grounded. Motor name plate has voltage,
phase, amp draw, and other motor information as well as wiring connection instructions.
This section concerns the electric motor, control box, and metal parts of the BaduJet super-sport.
CAUTION: Before installing the Speck Pump, read the entire pump owner's manual found in the pump box.
Consult local codes for minimum distance between pump and pool. Locate pump as close to the pool as practical.
CAUTION: There is 30 ft. of air tubing for the air buttons as well as 30 ft. of cable for the LED light included with the BaduJet
super-sport. The control box should be installed within this distance of the jet housing. If a longer distance is required,
please contact the factory regarding the use of smaller diameter air tubing.
BONDING: As required by the National Electrical Code, the electric pump motor must be electrically bonded to the pool
structure (reinforced bars, etc.) by a solid copper conductor not smaller than No. 8 AWG. Bonding lugs are provided on the
electric pump motor, stainless steel handles, and stainless steel cover. A 3ft length of 8 AWG insulated solid wire (10" of
insulation stripped back) is provided with the swimjet.
CAUTION: The strain relief MUST be completely tight around the bonding wire. The BaduJet super-sport II WILL LEAK if this
strain relief is left loose!
46
38/1
110
38/2
37
37
112
Figure 16
Installation of Knobs
21/1
111
17

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido