Comfort Glow KWP210 Manual De Instrucciones página 22

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
INSPECTING BURNERS
Check pilot flame pattern daily when in use and at least yearly by a qualified service agency.
PILOT FLAME PATTERN
Fig. 26 shows a correct pilot flame pattern. Fig. 27 shows an incorrect pilot flame pattern. The incor-
rect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool, which
shuts the heater off. If pilot flame pattern is incorrect:
• turn heater off (see "To Turn Off Gas to Appliance" on page 20)
• see Troubleshooting pages 23 through 26.
Fig. 26 - Correct Pilot Flame Pattern
WARNING: If yellow tipping occurs, your heater could produce increased levels of carbon
monoxide. If burner flame pattern shows yellow tipping, follow instructions under BURNER FLAME
PATTERN, page 21.
Notice: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater
and burn causing brief patches of orange flame.
BURNER FLAME PATTERN
Fig. 28 shows a correct burner flame pattern. Fig. 29 shows an incorrect burner flame pattern with
lifting, and excessive flame height.
If burner flame is incorrect:
• turn heater off (see "To Turn Off Gas to Appliance", page 20).
• see Troubleshooting, pages 23 through 26.
Fig. 28 - Correct/Normal Flame Pattern
with short flames with Control Knob Set
to High Flame (5)
Fig. 27 - Incorrect Pilot Flame Pattern
Fig. 29 - Incorrect/Abnormal Flame Pat-
tern with tall flames with Control Knob
Set to High Flame (5)
21

Publicidad

Capítulos

Tabla de contenido
loading