Connecting The Coolant; Risk Of Burns - Binzel WH Instructivo De Servicio

Antorcha de soldadura
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WH / WHPP

6.7 Connecting the coolant

WARNING

Risk of burns

The cable assembly overheats if the coolant level is too low.
• Wear the correct protective gloves.
• Check the coolant level at regular intervals.
NOTICE
• Make sure that the coolant supply and return have been installed properly. Coolant
supply = blue, Coolant return = red.
• Do not use any deionized or demineralized water as coolant or for tightness or flow tests.
This may impair the service life of your welding torch.
• We recommend the use of ABICOR BINZEL series BTC coolant for liquid-cooled
welding torches.
 Please consult the applicable safety data sheet.
1
Coolant return hose
Fig. 11
Ventilate the entire cooling system as follows when used for the first time and after every hose
assembly change:
1 Disconnect the coolant return hose (1) from the re-circulating cooling unit (2) and hold it
over a collecting device.
2 Close the opening at the coolant return hose (1) and open it again by repeatedly and
abruptly releasing it, until the coolant is flowing continuously and without air bubbles into the
collecting device.
3 Switch off the re-circulating cooling unit (2) and reconnect the coolant return hose (1).
BAL.0014 • 2019-01-16
1
2
Re-circulating cooling unit
Connecting the coolant
6 Putting into operation
2
3
3
Compressed air hose
EN - 15