This function allows to activate the indication of maintenance required after a certain number of operations, preset by the installer.
To activate and select the number of operations, proceed as follows:
Press the <PG> button, OFF is displayed, indicating that the function is disabled (default).
Select one of the numbers shown (from OFF to 100) by using the <+> and <-> keys . The figures express the value of hundreds of
cycles (e.g.: the number 50 means 5000 operations).
Press OK to activate the function. The PROG message is displayed.
When the flashing light flashes for around 10 sec at end of operation, this means that maintenance operations are needed.
RESET of the control unit. WARNING: Returns the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-button<PG> is pressed once more, the
control unit is reset.
Note: neither the transmitter codes nor the position and stroked of the gate leaf will be erased from the receiver.
The learning of the system stroke and the operating torque adjustment are carried out.
See paragraph SELF-LEARNING
It allows to type in an access protection code to the programming of the control unit.
A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F.
The default value is 0000 (four zeros) and shows the absence of a protection code.
While typing in the code, this operation can be cancelled at any moment by pressing keys + and – simultaneously. Once the password
is typed in, it is possible to act on the control unit by entering and exiting the programming mode for around 10 minutes in order to
allow adjustments and tests on functions.
By replacing the 0000 code with any other code, the protection of the control unit is enabled, thus preventing the access to any other
menu. If a protection code is to be typed in, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is shown, also in the case a protection code has been previously typed in.
- the value of the flashing character can be changed with keys + and -.
- press OK to confirm the flashing character, then confirm the following one.
- after typing in the 4 characters, a confirmation message "CONF" appears.
- after a few seconds, the code 0000 appears again
- the previously stored protection code must be reconfirmed in order to avoid any accidental typing in.
If the code corresponds to the previous one, a confirmation message "OK" appears.
The control unit automatically exits the programming phase. To gain access to the Menus again, the stored protection code must
be typed in.
IMPORTANT: TAKE NOTE of the protection code and KEEP IT IN A SAFE PLACE for future maintenance operan -
tions. To remove the code from a protected control unit, enter the programming mode with the password and
reset the code to the 0000 default value.
IF YOU LOOSE THE CODE, PLEASE CONTACT THE AUTHORISED SERVICE CENTER FOR THE TOTAL RESET OF
THE CONTROL UNIT.
After any LOGIC change or control panel reset, it is necessary to perform a self-learning procedure
OPERATING MODE WITH ENABLED/DISABLED ENCODER
With ENC LOGICS =ON:
- the anti-crash sensor is activated. Adjust sensitivity through parameters SEAV and SEAR in compliance with regulations in force.
An accurate adjustment of the motor brake (IBRA parameter) may help compliance with safety regulations as well.
- if braking is activated by setting parameter TSM from 0 to a higher value, it is necessary to perform a self-learning procedure.
Once the stroke is stored in memory, the control unit will manage braking automatically in both opening and closing phases. Braking
can be increased or decreased through parameter TSM.
In the event of power failure, the stroke is constantly updated and stored in memory together with the gate position.
With ENC LOGICS =OFF:
- the anti-crash sensor is disabled.
- if parameter TSM>0 (braking activated), the first operation is performed ad normal speed for the gate stroke memorisation, also in
the event of power failure.
MAINTENANCE (maci)
RESET (RES)
AUTOSET (AUTO)
PASSWORD (CODE)
ATTENTION:
(Menu Auto - See Stroke self learning)