If the transmitter code is already stored in the receiver, the remote radio learning can be carried out (without accessing the control
unit). The REM logics must be ON.
IMPORTANT: The procedure should be carried out with gate in the opening phase, during the TCA dwell time.
Proceed as follows:
1 Press the hidden key of the transmitter, the code of which has already been stored in memory.
2 Within 5 seconds, press the already memorised transmitter key corresponding to the channel to be matched to the new transmitter.
The flashing light switches on.
3 Within 10 seconds, press the hidden key of the new transmitter.
4 Within 5 seconds, press the key of the new transmitter to be matched to the channel selected at item 2. The flashing light switches
off.
5 The receiver stores the new transmitter code and exits from the programming mode immediately.
In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches,
control and safety) can be displayed. One segment of the display is linked to each input.
In the event of failure it switches on according to the following scheme.
F1
Protection fuse of transformer
F2
Output protection fuse of accessories and signals
F3
Output protection fuse for motor and blinker
Some messages that are displayed in the event of malfunctions are shown hereunder:
Motor
Err1
Error, PHOT O circuit check
Err4
Error, PHOT C circuit check
Err5
Error, encoder
ENC
Obstacle detection
Amp
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal
and the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a
specialised company.

TECHNICAL DATA

Power supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
18
TRANSMITTER REMOTE LEARNING
DIAGNOSTICS
FUSES
ERROR MESAGES
Technical assistance is required.
Check connections, alignment of PHOT O photocell or obstacle present.
Check connections, alignment of PHOT C photocell or obstacle present.
Error to connection or faulty encoder.
An obstacle present is indicated (anti-crash device).
WASTE DISPOSAL
230 Vac 50/60 Hz
1 motor 230Vac
1000 W
24Vdc 500mA max.
IP54
-20°C / +70°C