TECHNICAL FEATURES
Thermal power capacity
Thermal capacity hearth
Efficiency
Hot water production ∆T 30°C
Peak draw in the first 10 minutes
Reset
Boiler content
Water heater content
Heating circuit working pressure
Hot water working pressure
Heating delivery
Heating return
Cold water inlet
Hot water outlet
Re-circulation
Gas connection
Weight
Packaging
Heating expansion tank
Hot water expansion tank
CIRCULATOR FEATURES
Delivery/pressure available to the system
Trend
600
500
400
300
200
100
0
250
500
kW
kcal/h
kW
kcal/h
%
l/h
l
min
l
l
bar
bar
Ø
Ø
Ø
Ø
Ø
Ø
kg
mm.
630x700x1600
l
l
750
1000
1250
1500
Delivery (l/h)
28 MBS
27,8
23.908
30,45
26.187
91,2
780
148
9
42
100
3
6
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
138
630x700x1600
8
3
1750
2000
2250
28
32 MBS
31,9
27.434
34,5
29.670
92,5
820
170
8
42
100
3
6
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
8
3