Descargar Imprimir esta página

Chapter 5 - Technical Specification; Electric Motor - TECO 320 Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

CHaPTEr 5 - TECHNiCaL SPECiFiCaTioN

Capacity
Maximum lifting capacity
Minimum height of lift
Lifting time
Lowering time
Noise level
Total weight of the lift
Working temperature
Tank capacity
Voltage
Power
Frequency
N° poles
Speed
Motor enclosure type
Insulation class
Amperage
Motor connection must be carried out referring to the attached wiring diagrams.
Note: if we have not a specific request, the lift will be provided of a three-phases
motor (400 v).
Type gear
Flow rate
Continuous working pressure
Peak pressure
46
5.1 Size and main features (Fig. 5a - 5b - 5c)

5.2 Electric motor

240V
2,2 kW
3500 kg
1000 mm
120 mm
18 sec
25 sec
70 db
440 kg
+10° C a + 40° C
5 lt
50 Hz
4
1400 giri/min
B14
IP 54
14 A
5.3 Pump
gear
/g
3
3,65 cm
160 bar (2300 psi)
250 bar (3600 psi)
400V
2,6 kW
6,9 A