Recommendations For Installation - Elko EP AirWS-100 Serie Manual Del Usuario

Detector ultrasónico de llenado
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
Technical parameters
AirWS-100S
Power supply
Battery power:
Battery life:
Battery status view:
Setting
Setting:
Measured values:
Fill detection
Detection principle:
Range:
Resolution:
Input
Temperature measuring:
Range:
Sensitivity:
Accuracy:
Position detection
Tilt sensing:
Angle:
Accuracy:
Communication
Protocol:
Transmitter frequency:
Range in open space:
Protocol:
Transmitter frequency:
RCZ1 868 MHz
Range in open space:
Approx. 50 km**** Approx. 10 km**** Approx. 30 km****
Transmission power (max.):
25 mW / 14 dBm 25 mW / 14 dBm 200 mW / 23 dBm
Other parameters
Working temperature:
Storage temperature:
Operation position:
Mounting:
Protection degree:
Dimension:
* Depending on type and content storage.
** For service purposes.
*** Multiple frequency bands of B1 / B3 / B5 / B8 / B20 / B28.
**** Depending on network coverage.
Warning
Read the operating instructions before installing the device and putting it into opera-
tion. Instruction manual is designated for mounting and also for user of the device. It is
always a part of its packing. Installation and connection can be carried out only by a per-
son with adequate professional qualifi cation upon understanding this instruction man-
ual and functions of the device, and while observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling. In case you
notice any sign of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and its parts as elec-
tronic waste after its lifetime is terminated. Before starting installation, make sure that all
wires, connected parts or terminals are de-energized. While mounting and servicing ob-
serve safety regulations, norms, directives and professional, and export regulations for
working with electrical devices. Do not touch parts of the device that are energized – life
threat. To ensure the transmission of the radio signal, make sure that the devices in the
building where the installation is installed are correctly located. Unless otherwise stated,
the devices are not intended for installation in outdoor and damp areas, they must not
be installed in metal switchboards or in plastic cabinets with metal doors - this prevents
transmission of the radio frequency signal. iNELS Air is not recommended for control-
ling life-saving instruments or for controlling hazardous devices such as pumps, heaters
without thermostat, lifts, hoists, etc. - radio frequency transmission may be overshad-
owed by obstruction, interference, transmitter battery may be discharged etc., thereby
disabling the remote control.
AirWS-100L
AirWS-100NB
non-removable battery
2 x Li-SOCl
3.6V
2
up to 8 years according to frequency of
measurement and message transmission
message to the server
With a message from the server, magnetic keys,
RFAF/USB Service Key
message to the server
ultrasonic
5 - 300 cm
1 cm*
built-in sensor
-30 .. 85 °C
1 °C
± 3 °C
digital sensor
± 180 °
± 5 °
iNELS RF Control RFIO**
868 MHz
up to 20m
Sigfox
LoRa
868 MHz
LTE Cat NB1***
-30...+85 °C
-30...+85 °C
sensing contacts downwards
screws
IP65
Ø 97 x 62 mm
Assembly
1
a)
1. Drill four holes of the appropriate diameter into the substrate; corresponding to the
position of the holes in the sensor (you can use the sensor as a drilling template).
2a. Installation on the garbage can lid (material thickness 1-5 mm):
attach the sensor so that the ultrasonic sensors are directed into the container. Fasten
with suitable fasteners according to substrate. For example, a blind rivet Ø 5 mm, min.
15mm length or M5x15 screw with nut.
2b. Surface Mount:
insert the dowels into the holes, attach the detector with a suitable fastener so that the
NB-IoT
ultrasonic sensors are directed into the container. For example, a dowel screw, a screw Ø
of 5 mm and a length of 40 mm can be used as a suitable fastener.

Recommendations for installation

• The sensor is suitable for outdoor use. Operating conditions are consistent with con-
ventional chemically non-aggressive environments.
• Before mounting, check the range. Ensure the correct location - see Warning (must not
be placed in metal containers, etc.).
• The recommended working orientation is vertical, u ultrasonic sensors down to the
scanned area.
• Do not cover the sensor as this may reduce signal transmission.
• The sensor's immediate surroundings must remain free for proper detection. The bot-
tom of the sensor should not touch the contents even when it is full.
• Keep the ultrasonic sensors clean for proper operation.
Commissioning
To activate the detector, place the magnet on the POWER-ON magnetic contact for 5 sec-
onds and then on the magnetic contact SET for 3 seconds. The detector sends a start
message.
After activation, calibrate the detector by applying the magnet to the SET magnetic con-
tact for 9 seconds and place the sensor in the working position (close the waste con-
tainer lid). After successful calibration (40 seconds), the detector sends a message.
You can also perform calibration and detector setup in the application or using the RFAF/
USB Service Key and to lock the detector against manual adjustment.
2 / 2
2a
2b
b)