Heating
HVAC
HVAC
type
base
point
point
90 / 70
30 ˚C
85 ˚C
system
70 / 50
25 ˚C
75 ˚C
system
40 / 30
25 ˚C
45 ˚C
system
Temporarily change heating curve
If you change the programmed heating curve,
a parallel adjustment of +/–5 can be set, i. e.
a heating curve adjustment from the set value
of max. +/–25 K (+1
changed curve is not permanently stored but
only remains in place until the next time the
the program's temperature is changed.
P -adjust-
Frost
end
ment/
line
reduction
15 ˚C
3 ˚C
15 ˚C
3 ˚C
15 ˚C
3 ˚C
+5 K, –1
–5 K). The
If one of the PERM COMFORT, PERM
REDUCED or FROST PROTECTION programs
has been set the changed curve is kept until
the next program change.
Switch off heating (HEATING OFF AT)
With weather-dependent control you can
program the controller so that the heating
switches off at a set outdoor temperature.
GB
CONTROL
OT CONTROL
HEATING
OFF AT
15
°C
33