Adjusting The Pressure On The Pressure Regulator; Interruptions And Stopping Work - sewerin HP 105 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
5

Adjusting the pressure on the pressure regulator

The pressure will need to be adjusted in the following cases:
● first time the pressure regulator is used
● gas supply incorrect
Note
The device will not show a value for the pressure when switching
on if the pressure for the gas supply lies within the permissible
tolerance range.
If the gas supply is no longer correct, the device will show the
current pressure when switching on.
1. Assemble the system according to the instructions in sec-
tion 4.
2. Loosen the nut on the regulating screw (SW13).
3. Adjust the pressure on the regulating screw. Use a 5 mm Al-
len key.
● Turn clockwise to increase the pressure.
● Turn anti-clockwise to decrease the pressure.
The pressure has been set correctly once the device stops
showing a value for the pressure.
4. Tighten the nut on the regulating screw once more.
6

Interruptions and stopping work

The gas supply must be turned off in the event of any interrup-
tions or when stopping work for the day.
1. Close the valve on the fuel gas bottle.
2. Switch off the device.
3. Remove the pressure hose from the device.
14 │ English