TECHNICAL DATA
EX 125 ES
Rated input ..................................................................300 W
No-load speed .............................................. 7000–12000 min
Orbital travel diameter ..........................................2,4 mm ( 3/32")
Dimensions of grinding plate .......................................125 mm
Weight without cable ...................................................1,7 kg
Noise/vibration information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) ..............................80,0 dB (A)
Sound power level (K = 3 dB(A))..................................91,0 dB (A)
Wear ear protectors!
Total vibration values (vector sum in the three axes) determined
according to EN 60745.
Vibration emission value a
Uncertainty K = .............................................................1,5 m/s
GB
WARNING!
The vibration emission level given in this information sheet has
been measured in accordance with a standardised test given in EN
60745 and may be used to compare one tool with another. It may be
used for a preliminary assessment of exposure.
The declared vibration emission level represents the main
applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the
vibration emission may differ. This may significantly increase the
exposure level over the total working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or when
it is running but not actually doing the job. This may significantly
reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING!
Read all safety warnings and all instructions, including
those given in the accompanying brochure. Failure to follow
the warnings and instructions may result in electric shock, fire
and/or serious injury. Save all warnings and instructions for
future reference.
SAFETY INSTRUCTIONS
Wear ear protectors. Exposure to noise can cause hearing loss.
Appliances used at many different locations including open air
should be connected via a residual current device (FI, RCD, PRCD)
of 30mA or les.
Always wear goggles when using the machine. It is recommended
to wear gloves, sturdy non slipping shoes and apron.
Always disconnect the plug from the socket before carrying out any
work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
English
6
Random orbital sander
............................................7,4 m/s
h
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
The dust produced when using this tool may be harmful to health
(e.g. when working oak or beech wood, stones, paint, which could
-1
contain lead or other harmful chemicals). Do not inhale the dust.
Use a dust absorption system and wear a suitable dust protection
mask. Remove deposited dust thoroughly, e.g. with a vacuum
cleaner.
Do not use machines on any material containing asbestos.
This machine is suitable only for dry sanding.
SPECIFIED CONDITIONS OF USE
This random orbital sander is a versatile machine. The following
work can be carried out with it: Coarse sanding and grinding, Fine
sanding and polishing, Rubbing down weather-beaten paint,
2
Polishing up scratches on acrylic glass, Etc.
2
Do not use this product in any other way as stated for normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents: EN 60745, EN 55014-1, EN 55014-2,
EN 61000-3-2, EN 61000-3-3, in accordance with the regulations
2006/42/EC, 2004/108/EC
Winnenden, 2010-07-20
MAINS CONNECTION
Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect
to sockets without an earthing contact as the design conforms to
safety class II.
MAINTENANCE
The ventilation slots of the machine must be kept clear at all times.
Use only AEG accessories and spare parts. Should components need
to be replaced which have not been described, please contact one
of our service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the Article No. as well as the machine type printed on the label
and order the drawing at your local service agents or directly at:
AEG Elektrowerkzeuge, Max-Eyth-Straße 10, D-71364 Winnenden,
Germany.
Rainer Kumpf
Manager Product Development
Authorized to compile the technical file.