Special remarks
·
3 minutes protect after compressor stop
For protect compressor, there are at lest 3 minutes stopping after compressor stop.
·
5
minutes protect
Compressor must run 5 minutes at least once running. In the 5 minutes, compressor will not stop
even the room temperature reach the setting point unless you use remoter to turn off the unit.
·
Cooling operation
In cooling mode, the temperature can be set between18℃—32℃ .
The fan of the indoor unit will never stop running. It remains running even if the compressor stops working.
·
Heating operation
Since the air conditioner carries out the heating operation by drawing on the heat of the outside air (through
heating pump), the heating capacity may decrease if the temperature outside the room is too low. If the
heating effect is not so satisfying, use some other heating device together.
·
Anti-freezing function during cooling
When the temperature of the air from the indoor outlet is too low, the unit will run for some time under the
fan mode, to avoid frost or ice forming in the indoor heat exchanger.
·
Cold air prevention
In several minutes after the heating mode is started, the fan of the indoor unit will not run until the heat
exchanger of the indoor unit reaches a high enough temperature. That is because cold air prevention system
is operating.
·
Defrosting
When the outdoor temperature is too low, frost or ice may form in the outdoor heat exchanger, reducing
heating performance. When this happens, a defrosting system of the air conditioner will operate. At the same
time the fan in the indoor unit stops(or runs at a very low speed in some cases),a few minutes later, the
defrosting is over, and the heating operation restarts.
·
Blow out the survival heating air
When stop the air conditioner in normal operation, the fan motor would run in low speed for a while to blown
out the survival heating air.
·
Self Recovery of Power Break
When the power supply is recovered after break, all preset are still effective and the air-conditioner can run
according to the original setting.
Troubleshooting
CAUTION
When overflow of drain water from the indoor unit occurs, stop the operation and contact your contractor.
when you smell or see white smoke coming from the unit, turn OFF the main power supply and contact
your contractor.
1. If Trouble Still Remains ...
If the trouble still remains even after checking the following, contact your contractor and inform them of the
following items.
(1)Unit Model Name
(2)Content of Trouble
2. No Operation
Check whether the SET TEMP is set at the correct temperature.
5
Operation Manual