Technical Data; Electrical Connections - Telcoma K100 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
GB

TECHNICAL DATA

Electrical parameters:
Power supply
Frequency
Stand-by input
Maximum input
Max. motor power
Working temperature
Card size (W x H x D)
Transmitter model for the K100 control unit
Transmitter model for the K100 SW control unit
Reception frequency
Storage capacity

ELECTRICAL CONNECTIONS

For connections, refer to table 1 and figure 2.
With existing installations, a general check of the state of the wires (section, insulation, contacts) and auxi-
liary equipment (photocells, receivers, pushbutton boards, key selectors, etc.) is recommended.
Tips for correct installation:
1. The wires entering the control unit, in the sealed box version, should be connected without altering the
initial protection rating IP56 if possible.
2. The cross section of the cables should be calculated according to their length and absorbed current.
3. Do not use a single cable of the "multi-core" type for all the connections (line, motors, controls, etc.) or in
common with other equipment.
4. Use at least two cables for the installation, e.g.:
cable (A) minimum wire section 1.5 sq.mm
- power supply line – motor lines - courtesy/flashing light line
cable (B) minimum wire section 0.75 sq.mm
- auxiliaries power supply - controls – safety contacts.
5. When the control cables are very long (over 50 metres), de-coupling is advisable with relays mounted
near the control unit.
6. Any N.C. inputs (photocells, limit switches, fixed safety edge and stops) that are not used in the
control unit should be short-circuited with the common terminal terminal.
7. All the N.C. contacts linked with the same input should be connected in series.
8. All the N.O. contacts linked with the same input should be connected in parallel.
- THE INSERTION OF AN external, independent DISCONNECTING SWITCH (not supplied) of suita-
ble capacity for the load is envisaged for the control unit power supply.
- The equipment should be INSTALLED in a "WORKMANLIKE" manner by qualified personnel in
accordance with the laws in force and in compliance with standards EN 12453 and EN 12445 regar-
ding automation safety.
U.M.
Vac
Hz
mA
A
VA
°C
mm
serie
serie
MHz
Nr
K100
230 ±10%
50
20
6,3
1100
-20 +60
92x50x161
Tango
Tango SW - BLEU
433.920
140
29

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido