1
INSTALACIÓN Y PREPARACIÓN PARA EL USO
1.1
Running-in oil filter has to be installed after an overhaul or big repair
1.2
INSTALACIÓN
Esta sección contiene las instrucciones para instalar correctamente el compresor
(grupo compresor) Grasso. Antes de que el compresor (grupo compresor) esté
listo para el arranque inicial, deberá seguir las instrucciones de instalación de los
siguientes párrafos:
1.
2.
3.
4.
5.
6.
0089505esp_Pre-release_8
22.03.2017
Nota!
This is why and when the running in oil filters are required:
Advertencia
A running in oil filter has always to be installed after an overhaul or
big repair for the 1
The oil and oil oil filters have to be replaced by new oil and filters.
Due to running-in wear of liners and piston rings, it's normal that the
oil becomes grey during the 1
After 100 operating hours, the oil could slightly become clear again.
Advertencia
El compresor no tiene aceite, por lo tanto,NO arranque el compresor
antes de ser instalado y preparado de acuerdo con las instrucciones
de Grasso.
El Compresor (grupo compresor) debe ser nivelado y anclado firmemente a la
base.
Todas las tuberías deben están conectadas.
Someta el sistema y el compresor a presión para comprobar si existen fugas
(consultar Sección 1.3.2, Página 25)
Haga el vacío en el sistema para eliminar el aire y la humedad.
El cableado eléctrico debe estar conectado como indican los esquemas de
cableado. No conecte la corriente a la caja de control principal hasta después
de añadir aceite y comprobar el sentido de rotación.
El compresor debe estar lleno con el tipo y cantidad correctos de aceite lubri-
cante y debe estar lubricado previamente antes del primer arranque (Refer
Sección 4.5, Página 53).
INSTALACIÓN Y PREPARACIÓN PARA EL USO
Running-in oil filter has to be installed after an overhaul or big repair
st
100 hours of operation!
st
100 operating hours.
11