GB
1.5.3 TECHNICAL CHARACTERISTICS PASTRY TN DISPLAY CABINET (+4/+8°C)
CHARACTERISTICS
Voltage/Phases/Freq.
Power Consumption 230V
Climatic Class
Expansion Temperature
Condensation Temperature
Operating Temperature
Output
Refrigerated volume
Gas Type
R E M O T E C O N D E N S E R
UNITS 0-7 m
Voltage/Phases/Freq.
Power Consumption
Output -30°C
R E M O T E C O N D E N S E R
UNITS 7-22 m
Voltage/Phases/Freq.
Power Consumption
Output -30°C
Unit of
CLOUD
Measurement
1200 UC
V/Ph/Hz
230/1/50
W/A
1180/6.2
°C/UR
35°C/60%
°C
-10°C
°C
+45°C
°C
+4/+8°C
W
817
dm3/Cu.ft.
502/17.7
R404a
Unit of
Measurement
V/Ph/Hz
W/A
W
Unit of
Measurement
V/Ph/Hz
W/A
W
31
CLOUD
1700 UC
230/1/50
1570/8.3
35°C/60%
-10°C
+45°C
+4/+8°C
1096
576/20.3
R404a
1200
1700
230/1/50
230/1/50
432/2.6
664/4.2
817
1096
1200
1700
230/1/50
230/1/50
664/4.2
690/3.7
1096
1315
CLOUD
2200 UC
230/1/50
1735/8.0
35°C/60%
-10°C
+45°C
+4/+8°C
1315
747/26.4
R404a
2200
230/1/50
690/3.7
1315
2200
230/1/50
798/4.3
1448