GB
3.3 AUTOMATIC DEFROSTING
7KLV GLVSOD\ XQLW LV ¿WWHG ZLWK DQ DXWRPDWLF GHIURVWLQJ
system which is activated every 4 hours. Automatic
defrosting is designed to eliminate the ice which
forms on the evaporator tabs.
3.4 MANUAL DEFROSTING
Manual activation of the defrosting cycle is achieved
by pressing and holding the "UP" button (Fig.13,
pos.6). If the conditions are not suitable for the
defrosting process (for example, if the temperature of
the evaporator sensor is higher than the temperature
at the end of the defrosting cycle), the display will
ÀDVK WKUHH WLPHV WR LQGLFDWH WKDW WKH SURFHVV ZLOO QRW
be performed.
3.5 SYSTEM HCS
The defrost system (HCS Hermetic Closure System)
determines the frequency of defrosting in relation
to the actual needs. While holding the door closed
in the operator's side the time between two defrost
cycles increases, improving the preservation of the
product and reducing the consumption of electricity.
3.6 SWITCHING THE APPLIANCE OFF
Press the ON/OFF button (Fig.14a pos.2) to switch
off the display unit without using the disconnection
switch (Fig.14a pos.1). By doing this, the display unit
remains connected to the power supply, which means
that you can still switch the light on or off.
3.7 BT-TN OPTION (PASTRY BT DISPLAY CABINET)
If the option BT-TN is installed, next to the control
XQLW LV SODFHG D SXVK EXWWRQ VZLWFK ¿JE SRV
Fig.14a
(
(
(
(
(
(
°C
set
2
When the button is pressed the display will behave
like a pastry BT (-18 ° C).
When the button is at rest, the display will behave
like a pastry TN (+4 / +8 ° C).
3.8 BT-TN SWITCHING
To toggle the display in BT operation (-18 ° C) or TN
& LV VXI¿FLHQW WR RSHUDWH WKH FRUUHVSRQGLQJ
button to set the position.
CAUTION!
A f t e r t h e s w i t c h i n g p r o c e s s , w e
recommend the display unit is left to
stabilise for at least 30 minutes before
it is used.
CAUTION!
We recommend the display unit is cleaned
every time its operating mode is changed.
Fig.14b
1
0
41
1
1