Descargar Imprimir esta página

Hitachi NR 83AL NR 83AA Manual De Instrucciones E Instrucciones De Seguridad página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

I
L~L
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgflcm').
Connect the air hose.
Do not load any nails in the Nailer.
[] THE NAILER MUST NOT LEAK A[R.
Hold the Nailer downward and pull the trigger.
[] THE NA[LER MUST NOT OPERATE.
~~~ ~~.
~~C, fll'
~:~~
=~ '
~\~~\
~~
\~~\~~\~!
~
Pull Trigger
AD JUSTING
AIR
PRESSURE
(3) With finger otf the trigger, depress the push lever against
the workpiece.
[] THE NAILER MUST NOTOPERATE.
~~L~.
~l r~'
C~
-rf'
=
~~
~j ~)t
t~~t~~t
Do not pull Trigger
Depress Push Lever
(4) Without touching the trigger, depress the push lever
against the workpiece.
Pull the trigger.
[] THE NAILER MUST OPERATE
(5) With the Nailer otf the workpiece, pull the trigger.
Depress the push lever against the workpiece.
[] THE NAILER MUSTOPERATE.
(6) If no abnormal operation is observed, you may load nai[s in
the Nailer.
Drive nails into the workpiece that Is the same type to be
used in the actua] application.
[] THE NAILER MUSTOPERATE PROPERLY.
e Do not exceed 120 psi (8.3 bar 8.5 kgf/cm2).
Adjust the air pressure at recommended operating pressure
70 - 120 psi (4.9 - 8.3 bar 5 - 8.5 kgflcm2) according to the
length of nails and the hardness of workpiece.
The correct air pressure is the lowest pressure which will do
the job. Using the Nailer at a higher than required air pressure
unnecessarily over stresses the Nailer.
LOADING NAILS
O When loading nails into Nailer,
1 ) do not depress trigger;
2) do not depress push lever; and
3) keep Nailer pointed downward.
(1) Pull the nai[ feeder back until it latches.
u~
'J l'
V
IJ I~~
l~~.\l-' /1 /
= ~~ f-
1\
Nail
Feeder
@
(2) Insert nail strips one by one from above the magazine.
Two strips can be loaded at one time.
u-
\J ~
. J
l'
l I~ - = f
'~~l"' I ~~! ~\\~i\~)ii
~
+~~:~
@
Nail Strip
Magazine
-1i-