Condensate pump
DRAIN INSTALLATION MUST
MEET ALL STATE &
LOCAL PLUMBING CODES.
DRAIN AND
DRAIN TRAP
BY OTHERS
6.0
152.4 MIN
COUNTER
( PROVIDED BY OTHERS )
This unit is equipped with a condensate pump and approximately 25' of drain line. The drain
line is routed thru the lower back corner of the left-hand end from the factory. To reroute the
drain line out the right-hand side you will need to remove the display deck and coil cover/fan
housing to access the pump and drain line. Then remove the hole plugs in the right-hand end
and the hose and bushings from the left-hand end. Insert the bushings removed from the left-
hand end into the holes in the right-hand end and feed drain line thru the bushings. To close
the holes in the left-hand end, insert the hole plugs removed from the right-hand end. Route
drain line opposite of shown in diagram above.
CONDENSATE
PUMP
LOCATION
Refrigerated Self-Serve Merchandiser (High Profile)
Condensate Pump
IMPORTANT:
PUMP WILL NOT RUN
WITHOUT CONTINUOUS
RUN PLUG IN PLACE
DRAIN LINE
The vinyl drain line needs to be routed properly at
time of installation, vertical head cannot exceed 16'
and must be installed by qualified personnel only.
STANDARD
DRAIN LINE
LOCATION
OPTIONAL
DRAIN LINE
LOCATION
FAN
HOUSING
COIL
COVER
DISPLAY
DECK
Page 6