8.4.7 9 Long Distance Limit
Not applicable for this model.
8.4.8 15 Temperature Ctrl
Not applicable for this model.
8.4.9 16 Disp. Contrast
You can change the contrast of the display on a scale
from light to dark (25-55). Scroll between the values with
the up and down arrow keys and press select to confirm.
8.4.10 18 Distance
Not applicable for this model.
8.4.11 23 Filter Time
The default value is 400 working hours. After this time,
the filter replacement warning is displayed for filter
change.
If the dryer is placed in a dusty environment, it is recom-
mended to change filters more frequently.
Note! Keep in mind that if the filter is too dirty, the lamp
service life will be reduced as a result of impaired cool-
ing.
To reset, see 8.4.17.
8.4.12 25 Contin. Mode
The continuous mode is for sales demo purposes.
For safety reasons and for minimizing unnecessary wear-
ing down of the dryer, this mode must be used only in
exceptional cases.
8.4.13 36 Advanced Pin code
To change the code to your personal choice use the
up and down arrow keys to change the first digit, press
select to confirm. Continue with the second, third and
fourth digit. When completed press select to confirm the
new four digit PIN code.
Warning! Make sure that you remember the new code.
8.4.14 37 Dist. Unit
Not applicable for this model.
8.4.15 43 Advanced Code
It is possible to enable/disable the request for a PIN
code. This will remove the PIN code request in program
mode and the code 0000 will give you access to ad-
vanced settings.
Press select to confirm your choice.
8.4.16 44 Reset Prog. settings
You can reset to the pre-programmed factory settings for
all programs. Confirm by pressing yes.
Note! Also the programs 10-15 will reappear empty as
from factory.
8.4.17 45 Reset Filter Timer
After a filter change on the cassette, restart the filter
timer with this setting. Confirm by pressing yes to reset
the filter time counting.
To adjust the value in the filter timer, see chapter 8.4.11.
195996 rev 2
8.4.18 46 Statistics
The following information is available:
Run time
Shows accumulated working hours and minutes.
Start-ups
Shows the total number of starts of the dryer.
Σ (Total Power Consumption)
Presents the total energy consumption.
Φ (Average power consumption)
Presents the average consumption for all runs.
8.4.19 47 Perform Self test
The best fault trace software on the market has been
developed with this dryer. In this test all the important
input and outputs to and from the computer can be
tested. This test will give the opportunity for a quick and
accurate function verification of the different parts of the
dryer.
This test procedure is only available in English. By press-
ing the yes button you enter the first step of the self test.
To exit the self test, press the start/stop button.
Automatic testing includes the following:
Test 1: Push Button Test
All buttons on the control unit are tested. The corre-
sponding symbols are displayed by pressing the buttons.
Press enter for approx. three seconds in order to con-
tinue to the next step of the test program.
Test 2: Display Test
Verify that all pixels light up on the display. Press enter*
and check that all pixels go out. Press enter* to continue.
* or upper left software button
Test 3: Buzzer Test
Check that the buzzer sounds. Press enter or next to
continue.
Test 4: Cassette IR Test
The IR cassette lamps light up. Check that all the IR lamps
are lit. For safety reasons this test is limited to 10 sec-
onds. Press enter or next to continue.
Test 5: Ventilator Test/cassette
The ventilator in the cassette now starts. A sound from
the ventilator confirms that it is working. Press enter or
next to continue.
Test 6: Temperature Guards
The computer card has a temperature measuring device
that is seen on the display.
The temperature is shown in ºC or ºF depending on the
settings you have made.
The computer lifetime will be shortened if temperatures
are above 70ºC/158ºF during operation. If this happens
during drying, a new window will appear after the com-
pleted drying cycle saying "warning High temp Pc".
If the cassette internal temperature reaches 140ºC/284ºF,
the process will shut off giving an alarm.
EN
7

Publicidad

Tabla de contenido
loading

Productos relacionados para Hedson IRT QuickSpot 3

Este manual también es adecuado para:

Irt quickspot 6 with standIrt quickspot 6 wall mounted

Tabla de contenido