Remote Control Operation - BONAIRE 4500E Manual Del Proprietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BONAIRE WINDOW COOLER
Operation Instructions
1.
POWER (Start and stop operation)
2.
FAN – LOW (starts low fan speed but there will be no pump operation until button 5 is
pressed)
3.
FAN – MEDIUM (starts medium fan speed but there will be no pump operation until button
5 is pressed)
4.
FAN – HIGH (starts high fan speed but there will be no pump operation until button 5 is
pressed)
5.
Cool (turns pump and fan continues to operate on previously selected speed)
6.
4 HOURS CYCLE (Purge pump will run for 3 minutes every 4 hours) **Only applicable if
optional Purge pump is fitted
7.
8 HOURS CYCLE (Purge pump will run for 3 minutes every 8 hours) **Only applicable if
optional Purge pump is fitted
8.
12 HOURS CYCLE (Purge pump will run for 3 minutes every 12 hours) **Only applicable
if optional Purge pump is fitted
9.
PUMP ONLY (turns pump on at first button press & turns pump off at second button
press. NOTE: there will not be any fan operation with this function, pump only)
NOTE:
For pump only operation the
1. The pump only button
2. If the cooler is running pressing
before
pressed, it will only turn off fan).

Remote control operation

button is selected, the operation will be as follows:
can only be activated only when the power is on.
will turn off fan and turn on main pump (If the main pump is on