AGB OPERA BIT Guía De Usuario página 19

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Setup Cards (fig. 16)
Setup Cards (fig. 16)
5.3 Supervisor Card
See paragraph 4.3.
5.4 Activate Serial
See the instructions provided with USB-serial cable.
5.5 Deactivate Serial
See the instructions provided with USB-serial cable.
5.6 Cards to change the lock status
The following cards allow to change the lock status in special situations, introducing new rules to control access
in that period.
Each of the following Setup Cards changes the status of function when it is approached to the lock.
The card works as a button: it turns on/off according to the lock status.
For one of each cards, if the function is off in the lock, the card activates it; if the function is on, the card disables
it.
Card name
Hallway side
Offi ce card - it
The
enables all the
blocked
cards
valid card will be
(only for local
approached or the
or specifi c ser-
emergency
vices)
will be operated.
Offi ce card -
The
hold closed
blocked
valid card will be
approached or the
emergency
will be operated.
Offi ce card -
The handle is always
hold open
unlocked.
To disable the function, approach again the Setup Card to the lock.
1) WITH CURRENT DATE AND TIME
• • Menu:
Setup
Cards.
• Click on Card setting for current date/time, then Write Card
• Approach a Neutral Card to the Reader.
• Bring the card just written to the lock of the room that must be updated and ap-
proach it to the reader.
• • Convert the card in a Setup Card summer/winter time (paragraph 5.1).
• Put the card used among the other Neutral Cards.
2) WITH ARBITRARY DATE AND TIME
• • Menu:
Setup
Cards.
• Click on Card setting for date/time, change the value in the cell and then Write
Card
.
• Approach a Neutral Card to the Reader.
• Bring the card just written to the lock of the room that must be updated and ap-
proach it to the reader.
• • Convert the card in a Setup Card summer/winter time (paragraph 5.1).
• Put the card used among the other Neutral Cards.
Who can enter
handle
stays
All the Guest cards,
until
a
Operator cards and
Supervisor cards of
the installation.
cylinder
The emergency me-
chanical key.
handle
stays
Only the Supervisor
until
a
card of installation.
The emergency me-
chanical key.
cylinder
The door is open
without the need to
give other cards or
keys.
Opera Bit Manager
Opera Bit Manager
Opera Bit Manager
Opera Bit Manager
Who can't enter
Mode on:
With Neutral cards,
Setup cards and the
Activation card.
Mode off :
Mode on:
Only the Supervisor
card can enter.
Mode off :
Mode on:
Mode off :
EN
.