Replace:
Incoming controller messages that match a fader are passed through the PC 1600x until the fader is moved. The
matching incoming controller messages are filtered until the Exit button is pressed while on the Main page. This
mode allows direct replacement of data in an existing stream of controller messages.
Update:
Incoming controller messages that match a fader are passed through the PC 1600x until the fader is moved. The
data sent when the fader first moves will always match the last value that passed through the PC 1600x, regard-
less of the position of the fader. The matching incoming controller messages are filtered until the Exit button is
pressed while on the Main page. This mode allows seamless modification of data in an existing stream of control-
ler messages.
To define a fader as a continuous controller:
1. First, set the function to "Controller." Press the left, right, or Exit button to de-select the edit field, then press
the up button to move to the following page:
2. Cursor over to the "Chnl" field and set the MIDI channel for the controller message. Incrementing the
channel number above 16 will display "ChOut." When "ChOut" is selected, the controller message
will be transmitted on the global MIDI transmit channel from the Utility menu.
3. Cursor over to the "Num" field to set the controller number to be transmitted. See Appendix C for a list of
MIDI Controller numbers.
4. With no parameters flashing, press the up direction button to access the following page:
5. Cursor left or right to the Min or Max field and edit the value as necessary (range=0–127).
6. With no parameter flashing, press the up direction button to access the mode page:
7. Cursor right or left to access the "Mode" parameter. Select either "Merge," "Replace," or "Update."
MASTER FADER/CV
Several faders can be grouped together and controlled by another fader. This is done by defining a single fader or
CV pedal as the master fader as shown:
1. Set the function to "Master Fader". Next, press the up direction button when the function field is not blink-
ing. The following page will be displayed:
2. Cursor right once to activate the "Master of" field. Set this field using the up/down direction buttons, the
data wheel, or the current fader. Moving any fader will select the fader moved.
3. The "Yes" or "No" on the right shows whether the fader in the "Master of" field is being controlled by the
current master fader. To toggle between "Yes" and "No," simply press the right direction button. The
"Master of" field will remain active.
FDR01: Chnl
Num
16
007
FDR01: Min
Max
000
127
FDR01:
Mode
Merge
FDR01:
Master of
Fader01= No