1. WARNINGS
Before attempting any work on the control board (connections, main-
tenance), always turn off power.
Install, upstream of the system, a differential thermal breaker with
adequate tripping threshold.
Connect the earth cable to the appropriate terminal on the J7 con-
nector of the equipment (see fig.2).
Always separate power cables from control and safety cables (push-
button, receiver, photocells, etc.). To avoid any electric noise, use
separate sheaths or a shielded cable (with earthed shield).

2. TECHNICAL SPECIFICATIONS

Power supply
Absorbed power
Motor max. load
Accessories max. load
Operating ambient tempe-
rature
Protection fuses
Automatic / "Stepped" automatic / Semi-au-
tomatic / Safety devices / Semi-automatic B
Function logics
/ Dead-man C / "Stepped" semi-automatic
Work time
Pause time
Thrust force
Open / Pàartial opening / Safety devices
Terminal board inputs
at opng. / Safety devices at clsng. / Stop /
Opening and closing limit-switches / Enco-
On-connector inputs
Flashing lamp - Motor - 24 Vdc accessories
Terminal board outputs
power supply - 24 Vdc indicator-light / Timed
Rapid connector
Programming
Basic mode programmable
Function logic - Pause time - Thrust Force
functions
Torque at initial thrust - Braking - Fail safe
- Pre-flashing - Indicator-light/Timed output -
Advanced mode program-
Opening and closing safety devices logic -
mable functions
Encoder - Decelerations - Partial opening
time - Work time - Assistance request - Cycle
CONTROL BOARD SPRINT 382
230 V~ ( +6% -10%) - 50 Hz
10 W
1000 W
0,5 A
-20 °C +55 °C
2 (see fig. 1)
/ Mixed Log. B+C
Programmable (from 0 to 4 min.)
Programmable (from 0 to 4 min.)
Adjustable over 50 levels
Edge / Power supply + Earth
der
output. - Fail safe
5-pin card connection for receivers
3 keys (+, -, F) and display, "basic" or
"advanced" mode
- Gate direction
counter

4. ELECTRIC CONNECTIONS

3. LAYOUT AND COMPONENTS

DL
SIGNALLING AND PROGRAMMING DISPLAY
Led
INPUTS STATUS CONTROL LED
J1
LOW VOLTAGE TERMINAL BOARD
J2
CONNECTOR FOR RECEIVER
J3
ENCODER CONNECTOR
J4
CAPACITOR CONNECTOR
J5
LIMIT -SWITCH CONNECTOR
J6
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD
J7
POWER SUPPLY TERMINAL BOARD 230Vac
F1
MOTORS AND TRANSF. PRIMARY FUSE (F 5A)
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
F2
F
"F" PROGRAMMING PUSH-BUTTON
-
"–" PROGRAMMING PUSH-BUTTON
+
"+" PROGRAMMING PUSH-BUTTON
12
Fig. 1
Fig. 1
* Only if don't use J4 connector
* Only if don't use J4 connector
Fig. 2
Fig. 2

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido