Genius JA592 Instrucciones Para El Uso página 12

Equipo electrónico para portones de tipo batiente 230v
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
1.
WARNINGS
Important: Before attempting any work on the control board
(connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker (Residual
Current Device) with adequate tripping threshold.
- Connect the earth cable to the appropriate terminal on the J3
connector of the equipment (see fig.2).
- Always separate power cables from control and safety cables
(push-button, receiver, photocells, etc.). To avoid any electric
noise, use separate sheaths or a shielded cable (with earthed
shield).
- Earth conductors of motors, control board and power supply must
be connected to suitable screw terminals having such dimensions
to receive wires with section up to 2.5mm 2 . The terminals must be
firmly secured near the power supply terminal of the board, with no
possibility of turning. No more than one wire must be connected to
each terminal. This terminal must be marked with the symbol
- The control board must be housed in a plastic enclosure with minimum
dimensions 250mmx190mmx90mm and with IP55 protection class or
more, using tubes and/or cable glands having the same IP class.
2.
TECHNICAL SPECIFICATIONS
Power supply
Absorbed power
Motor max. load
Accessories max. load
Electric lock max. load
Operating ambient temperature
Protection fuses
Function logics
Automatic / Semi-automatic / "Stepped" safety devices /
Semi-automatic B / Dead-man C / "Stepped" semi-automatic
Opening/closing time
Pause time
Closing leaf delay
Opening leaf delay
Thrust force
Terminal board inputs
Opening safety devices / Closing safety devices / Power supply + Earth
Terminal board outputs
- 24 Vdc indicator-light - Fail safe - 12 Vac electric lock power supply
Rapid connector
Selectable functions
Opening and closing leaf delay - Reversing stroke -
Fail safe - Closing safety devices logic - Pre-flashing
Programming key
4.
ELECTRIC CONNECTIONS
J3
PE N
L
COM
MAIN
Earth
terminal
230 VAC
50 Hz
ATTENTION: when
connecting, observe the
sequence phase/neutral.
NB.: Capacitors are supplied with the operators.
CONTROL BOARD JA592
230 V~ ( +6% -10%) - 50 Hz
10 W
800 W
0,5 A
15 VA
-20 ∞C +55 ∞C
2 (see fig. 1)
Programmable (from 0 to 120 s)
0, 10, 20, 30, 60, 120 s
0, 5, 10, 20 s
2 s (Can be disabled with the dip-switch)
Dip-switch adjustable on 8 levels for each motor
Open / Open free leaf / Stop / Limit-switch
Flashing lamp - Motors - 24 Vdc accessories power supply
Rapid connector 5 pins
Logics and pause times - Thrust force -
Simple or Advanced work time learning,
with or without Limit-switch and/or encoder
1
2
3
4
5
6
7
8
OP
OP
COM
CL
LAMP
M1
M2
C1
C2
230 VAC
M1
M2
max.60W
TOTALLY OPEN
OPEN LEAF 1
3.
LAYOUT AND COMPONENTS
F1
F1
J3
.
J3
1
2
L
PE N
OP
COM
M1
MAIN
Led OP_A
Led OP_B
Led STOP
Led FSWCL LED: CLOSING SAFETY DEVICES
Led FSWOP LED: OPENING SAFETY DEVICES
Led FCA1
Led FCC1
Led FCA2
Led FCC2
DL10
J1
J2
J3
J4
J5
J6
F1
F2
F
DS1
DS2
J1
J4
9 10 11 12 13 14 15 16 17 18 19
A
B
CL OP
STP
OPEN
FSW
STOP
10
F2
F2
OP_A
STOP
J1
J4
J4
J1
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19
OP
A
B
CL OP
STP
COM
CL
LAMP
M2
OPEN
FSW
TOTALLY OPEN LED
LED: OPEN LEAF 1 / CLOSE
LED STOP
LED: LEAF 1 OPENING LIMIT-SWITCH
LED: LEAF 1 CLOSING LIMIT-SWITCH
LED: LEAF 2 OPENING LIMIT-SWITCH
LED: LEAF 2 CLOSING LIMIT-SWITCH
LED: TIME LEARNING SIGNALLING
LOW VOLTAGE TERMINAL BOARD
RAPID CONNECTOR 5 PINS
230 VAC POWER SUPPLY TERMINAL BOARD
MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD
INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BOARD
LIMIT-SWITCH AND ENCODER TERMINAL BOARD
MOTORS AND TRANSFORMER PRIMARY WINDING FUSE (F 5A)
LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)
TIME LEARNING SELECTION PUSH-BUTTON
1ST GROUP OF MICROSWITCH PROGRAMMING
2ND GROUP OF MICROSWITCH PROGRAMMING
J5
20 21
+
+
-TX
LOCK
-
-
-
+24V
FSW
W.L.
24 Vdc
3 W
For connection
of the photocells
12 V ac
and safety
devices, see
LIMIT-SWITCH
paragraph 4.1.
DS2
DS1
1 2
3 4
5
6 7 8
9 10 11 12
1 2 3 4
J2
J2
F
F
DL10
DL10
FCC1
FCC2
OP_B
Led
FSWCL
FSWOP
FCA1
FCA2
J6
J6
J5
J5
22
23
24 25
20 21
+
+
-TX
LOCK
-
-
-
+24V
FSW
W.L.
Fig. 1
J6
22
23
24 25
Fig. 2

Publicidad

Tabla de contenido
loading