Controller Mode
5. RESPONSE
This menu is for setting RESPONSE function of the camera which is connected Controller.
At the [CONTROLLER SETUP 1
] menu, press the
button (see p.31).
Press the 1 button to open the Response Setup screen.
Press the 1 button to set the controller RESPONSE
setting to ON. The controller automatically restarts to
apply the change.Press the 2 button to set the
controller RESPONSE setting to OFF. The master
controller display shows the setup screen for the
number of the connected subcontroller.
Press the 1 ~ 4 button to set the number of the desired
sub controller. The controller automatically restarts to
apply the changed settings after entering the number.
- 1: Sets the number of sub-controllers to 4 including
the master controller.
- 2: Sets the number of sub-controllers to 8 including
the master controller.
- 3: Sets the number of sub-controllers to 12 including the master controller.
- 4: Sets the number of sub-controllers to 16 including the master controller.
• Set the maximum number of sub-controllers, to shorten the sub controller data loading time
by making the master controller memorize the number of sub-controllers.
• If Response is set as ON, a maximum of 12 sub-controllers only can be selected.
Caution
• If the camera RESPONSE is set to two-way reception (RESPONSE ON), the controller
RESPONSE menu must be set to ON. If the camera RESPONSE is set to one-way reception
(RESPONSE OFF), the controller RESPONSE menu must be set to OFF.If this is not followed,
the system may have a configuration conflict. For more information on the camera RESPONSE
settings, direct your inquiries to the installation vendor. If the DIP switch for the camera
connected to the controller is set to two-way reception (RESPONSE ON), this menu can be
used to set up the RESPONSE value for the controller and the number of sub-controllers.
34
SYSTEM CONTROLLER
User's Manual
Controller Mode
For information on camera RESPONSE settings (DIP switch settings), refer to the camera manual.
5-1. SPD-3750T/3750/3350 DIP Setup
SW2- #8
RESPONSE Setup
5-2. SPD-3300/3000/2300 DIP Setup
SW3- #1
RESPONSE Setup
5-3. SPD-1000 DIP Setup
SW2- #6
RESPONSE Setup
35
SYSTEM CONTROLLER
ON
OFF
Response
No Response
ON
OFF
Response
No Response
ON
OFF
Response
No Response
User's Manual