39346 / ZW4201
Firmware Version V5.21
ADVANCED OPERATION
The following Advanced Operation parameters require that you have a controller that supports the advanced
configuration command class.
All On/All Off
Depending upon your primary controller, this Z-Wave module can be set to respond to ALL ON and ALL OFF
commands in up to four different ways. Some controllers may not be able to change the response from its default
setting. Please refer to your controller's instructions for information on whether or not it supports the
configuration function and if so, how to change this setting.
The four possible responses are:
- It will respond to ALL ON and the ALL OFF commands (default).
- It will not respond to ALL ON or ALL OFF commands.
- It will respond to the ALL OFF command but will not respond to the ALL ON command.
- It will respond to the ALL ON command but will not respond to the ALL OFF command.
Association Group Statement
•
This device supports Association Command Class (3 Groups)
•
Association Group 1 supports Lifeline, Binary Switch Report
•
Association Group 2 supports Basic Set and is controlled with the local load
•
Association Group 3 supports Basic Set and is controlled by double pressing the On or Off button
•
Each Association Group supports 5 total nodes
Manual Reset
1. If plugged in, unplug the Switch from the receptacle
2. Press and hold the top button for at least 3 seconds while you plug the switch into a receptacle.