Technical Information - Palazzetti Sunny Fire Ecomonoblocco Serie Generalidades - Advertencias - Instalación - Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Depending on the type and quantity of wood, the
remaining embers and chimney draft, this reheating
phase takes about 5 minutes before the combustion air
can be throttled again.
12. If no further replenishment is planned (-7.4.12-), the
adjustment lever may be fully closed, using the "cold
hand", as soon the remaining embers are almost gone.
Finished burning!
8 TECHNICAL
INFORMATION
8.1
HEATING BETWEEN SEASONS
Proper chimney draft is the fundamental prerequisite for
the proper operation of a replace. The draft is dependent
on outside temperatures, therefore also on seasons.
When the seasons change – winter to spring and summer
to autumn – higher outside temperatures may reduce the
draft, manifesting by poor burning or increased smoke
generation.
WHAT CAN YOU DO?
• Empty the ash catcher and grid before lighting a re.
Insert the ash grille with the engraved logo (where
applicable) facing downwards.
• If the chimney draft is weak, a bigger "pilot re" should
be created using small, easily ignitable wood, to reach
the required temperature quicker and thereby create
a stable draft in the chimney.
• Leave the air supply adjustment lever turned to the
right (maximum air supply) if necessary, even after the
re has started. It is important to give the re enough
combustion air to stabilize the chimney draft, but no
more than that, to avoid burning too much wood too
quickly.
• Do not turn the adjustment lever fully to the left in
the last phase of burning down. This may cause the
chimney draft to collapse and lead to smouldering in
the replace insert.
• To avoid resistance build-up in the bed of embers, the
ash should frequently be carefully prodded to prevent
the ash grid from blocking air ow.
8.2
COMBUSTION AIR – AMBIENT AIR – FRESH
AIR
• The provisions for supply of combustion air are not
allowed to be changed and must be open.
• To avoid heat build-up in the unit, the air outlet grids
or apertures must be free and open whilst a re is
burning.
• No objects made of ammable materials may be
placed within 80 cm of the radiating area of an
open replace, measured from the front of the re
compartment opening.
• No objects made of ammable materials shall be
deposited on open replace surfaces.
• Do not use equipment generating negative pressure
on the same level in the same interconnected ambient
air (e.g. extractor hood in the kitchen). This creates a
risk of smoke escaping into the living room.
• No ammable objects or materials may be placed on
or installed in the replace cladding within 5 cm of the
radiating area if the surface temperature may reach
85 °C or higher.
• Bear in mind that a replace heats up signi cantly
when in operation. The pane may reach temperatures
in excess of 300 °C. Always use the supplied glove or
operating handle ("cold hand").
• In Germany, fireplaces may only be operated in
accordance with 1.BlmSchV.

Publicidad

Tabla de contenido
loading

Tabla de contenido