6. INSTALLATION GUIDE

6.1 Before mounting:

1. Check the integrity of the package.
2. Make sure the valve is as per order.
6.2 Mounting:
1. Remove cap from the valve inlet.
2. Remove the protection cover from the
cylinder.
3. Replace existing "OR" seal with the new seal
supplied.
4. Mount the valve with four screws and the
corresponding washer provided.
Position the valve to align it with the feed line.
5. The tightening torque for mounting screws is
indicated on Table 3.
6. Connect oil feed line.
table 3 - Screw tightening torque
VALVE TYPE
VC 3006/B - 3/4"
VC 3006/B - 1"
VC 3006/B - 1"1/4
VC 3006/B - 1"1/2
VC 3006/B - 2"
VC 3006/B - 2"1/2
Screw
Torque [Nm]
M8 - 8.8
M10 - 8.8
"schnorr" washer
screw
valve VC 3006
terminal connector
POSSIBLE MOUNTING POSITION
± 90°

MOUNTING DIAGRAM

20
cylinder
oil inlet
40
O-R
protection cover +
washers and screw
19
± 90°
± 90°
data plate
GB
± 90°