6.3 Mounting of tubing joints/connections
A - Mounting of the copper tube
1. Screw the end connection in its fit hole.
2. Cut the tube at the desired length and check that the cut is perpendicular with the tube.
3. Slightly deburr the tube inside and outside.
4. Oil the connections threading.
5. Screw the blocking gear until it stops.
6. Fix for ¼ rev. spanner and fox-wedge.
7. Loose and check that the cutting ring has engraved the tube all around.
8. Repeat operations 5 and 6.
B - Mounting the flexible tube
1. Screw nipple 1/8" in its hole.
2. Screw the female rotating component on the nipple until it blocks and fix for 1/4 rev.
1. Terminal straight connection G 1/8"
2. Cutting ring
3. Copper tube Ø 6x1
4. Blocking gear
5. Nipple1/8"
6. Nipple 6/16"