CAUTION: Hold the hood until it is completely secured to the wood mounting strip.
!
1. Run power cable to installation location. Remove the
electrical compartment cover. Insert the cable in the hood
and tighten the wire clamp to secure the cable.
2. Rest the back cavity of the hood on the wood mounting
strip.
3. Secure the hood to wood mounting strip with 4 screws
no. 8 x 3/4" provided at locations shown. Drill (3) 3/16" size
holes into the drywall for wall anchors through the existing
holes in the inside hood back in the locations shown. Then,
install the three wall anchors with the remaining
no. 8 x 3/4" screws and the 3 washers provided.
WARNING: Risk of electrical shock. Electrical wiring must be done by qualifi ed personnel in accordance
with all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
1. Connect cable using provided wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and GREEN
or bare wire under GREEN ground screw.
DO NOT FORGET TO CONNECT THE GROUND.
CAUTION: The ORANGE wire (A) is for make-up
!
air device connection only. If there is no make-up
air device, never remove the cap on the ORANGE
wire end.
2. Reinstall wiring cover.