For non-ducted installation, a recirculation kit 55673 or 55683 (sold seperately) must be installed. See installation
instructions included with the non-duct kit 55673 or 55683.
Plan where and how the ductwork will be installed.
If using 7" or 8" round ducts, use a transition . Use 2" metal foil duct tape to seal duct joints.
The minimum hood distance above cooktop must not be
less than 24". A maximum of 30" above cooktop is highly
recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
NON-DUCTED INSTALLATION
INSTALL DUCTWORK
ROOF CAP
CABINET or
12"
DECORATIVE FLUE
HOOD
24" TO 30" ABOVE
COOKING SURFACE
HH0224A
TYPICAL DUCTWORK
PREPARE THE HOOD LOCATION
7" or 8" ROUND
or 3¼" x 10" DUCT
WALL CAP
7" or 8" ROUND
or 3¼" x 10"
RECTANGULAR
ELBOW
CABINET,
DECORATIVE FLUE
MINIMUM DISTANCE BETWEEN
THE HOOD AND COOKTOP: 24''
DISTANCE BETWEEN THE HOOD
HH0226A
MINIMUM AND MAXIMUM DISTANCE OVER
7
CEILING
TOP OF WOOD
A
MOUNTING STRIP
A + 2''
HOOD
RECOMMENDED MAXIMUM
AND COOKTOP: 30''
STANDARD 36"
HIGH COOKTOP
COOKTOP