PASS-THROUGH (GS3125 Series only)

This feature allows the Power Series PC1864 control panels (PC 1864 4.1 EU, PC 1864 4.2 EU, PC 1864 4.2 ADT Spain,
PC 1864 4.5 ADT Spain, PC 1864 4.5 EU) to be programmed remotely via GPRS using the GS3125 Communicator and
the DLS IV INT software application updated with the "Driver pack for the GS3125". The Communicator must be
properly programmed before connecting it to the Power Series PC1864 control panel.

Programming the Alarm Communicator

To program the Communicator, see the "Programming the Device" section. Using the GS3100 Series Console, perform
the following operations:
1. Enable the Remote Programming on the Communicator (see "GPRS->Remote Programming" section).
2. Program a valid Access Point Name (APN) on the Communicator (see GPRS section).

Connecting the Communicator to the Power Series PC1864 panel

To connect the Power Series PC1864 control panel to the GS3125 Communicators you will need a PCLINK-PCLINK cable
(see Figure 6) connecting the PC-LINK connector [9] on the Communicator with the PC-LINK connector on the control panel,
making sure that you insert the connector the right way round.
     CAUTION: connect the PCLINK/PCLINK cable as shown in Figure 6, please note that the white wire on the PCLINK-PCLINK
cable connector must be connected to pin 4 of the PC-LINK connector on the Communicator and on the control panel.

Operations to perform on the Power Series PC1864 control panel

Perform the following checks on the Power Series PC1864 control panel:
1. Check section 382 on the control panel: option 5 must be set to ON.
2. There must be NO faults, the GREEN LED on the control panel must be ON: this shows that the control panel sees the
GS3125 Communicator as connected and working.

Operations to perform on the PC

Perform the following operations on the PC before programming remotely with the DLS IV INT software application :
1. The PC must have a public IP address and a public port for incoming connections to the DLS IV INT software.
2. The firewall and the router must allow the PC to connect the public port to port 51004 of the DLS IV INT software application.
3. Make sure you can access the public port of the router from another PC to see if the DLS IV INT software can be reached
from the device.
PC1864
Fig. 6 - Connecting the Communicator to a DSC Power Series control panel via a PCLINK-PCLINK cable.
74
GS3125
PC-LINK