Installation
The installation and location of all Safety drench showers, eye and eye/face washes must comply
with the requirements of ANSI Z358.1.
Emergency equipment must be supplied with tepid water (60-100°F/ 15.6-37.8°C). Any prolonged
exposure to near freezing water affects the body's ability to maintain body temperature, increasing
the risk of hypothermia.
Flush the water supply lines before beginning installation and after installation is complete. Test
the unit for leaks and adequate water flow. Main water supply to the eyewash should be "ON" at all
times. Provisions shall be made to prevent unauthorized shutoff.
The ANSI Z358.1 standard requires an uninterrupted supply of flushing fluid. Bradley plumbed
emergency fixtures require a minimum of 30 PSI (0.21 MPa) flowing pressure. Flushing fluid should
be tepid per ANSI Z358.1.
Weekly activation must be conducted on all plumbed emergency equipment to ensure a suitable
flushing fluid supply is present and any sediment build-up in the supply line is cleared. Emergency
Equipment should be inspected monthly to address any maintenance issues ensuring the
equipment is in good operating condition and that there are no signs of wear.
Workers who may come in contact with potentially hazardous materials should be trained regarding
the placement and proper operation of emergency equipment per ANSI Z358.1.
Before installing this product ensure that there are adequate clearances around the product and
activation of the product does not interfere with other products or obstructions
For classic eye/face wash units, avoid cleaners containing organic solvents, alcohols, and
hydrocarbons. Rinse with water after cleaning.
Read this installation manual completely to ensure proper installation, then file it with the owner
or maintenance department. Compliance and conformity to drain requirements and other local
codes/ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before discarding
any packaging material. If any parts are missing, do not begin installation until you obtain the
missing parts.
For questions regarding the operation or installation of this product, visit bradleycorp.com or
call 800.BRADLEY (800.272.3539).
Product warranties may also be found under "Products" on our web site at bradleycorp.com.

Supplies Required:

Piping to ½" NPT water supply inlet on unit
Pipe sealant
Inlet strainer (recommended)
Sign-mounting hardware
Bradley • 215-1326 Rev. V; ECN 15-05-042
WARNING
NOTICE

IMPORTANT

Local codes may require the installation of a backflow prevention
valve to complete proper installation. Compliance with local codes
is the responsibility of the installer. Valve must be tested annually
to verify that it is functioning properly. Backflow prevention valves
are not included with the fixture and may be supplied by the
contractor or purchased from Bradley Corporation.