rEPLAcinG tHE cLAMP cABLES
1.
Remove the two screws on the cover plate, and tilt it out
of the slots on the bottom.
2. Remove the screws on the terminals using a 6 mm hex
wrench. These will be torqued down tight, so you will
probably need to use the long end. Take care when
removing the screws to prevent stripping the hole. To
prevent damage, it is recommended you use an open
ended wrench to keep the terminal from spinning.
EEBc500-int-Z
3. the strain reliefs are held in by three spring tabs. While
pulling on the cable (opposite side of strain relief), push
on the bottom tab to get it out first, then squeeze the two
side tabs together to remove the strain relief from the
hole.
4. Follow these steps in reverse to assemble the new cable.