Remington REM-80-OFR-O Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Service (Continued):
NOZZLES:
Nozzles should be cleaned or replaced at least
once per heating season. Contaminated fuel
could make this necessary immediately. To
clean dirt from nozzle, blow compressed air
through nozzle front. It may be necessary to
soak nozzle in clean Kerosene or diesel to help
loosen any particles (see Figure 14a and 14b).
80-OFR-O Nozzle
Figure 14a
125-OFR-O Nozzle
Figure 14b
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
MAINTENANCE (CONT.)
PHOTOCELL:
The photocell should be cleaned at least once
per heating season or more depending on
conditions. Use a cotton swab and water or
alcohol to clean the lens of the photocell.
Be certain to reinstall the photocell in proper
position as shown below (see Figure 15).
FILTERS:
The fuel filter and oil filter should be cleaned
at least twice per heating season by rinsing
it in clean Kerosene or diesel. Contaminated
or old fuel could make cleaning necessary
immediately.
10
Photocell
Kerosene Radiant Heater User's Manual
Figure 15

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Rem-125-ofr-o

Tabla de contenido