Maintenance and care
The appliance is maintenance free.
DANGER
Risk of electric shock.
Prior to all work on the appliance,
switch off the appliance and pull the
power plug.
Clean the sieve in the water connection
Clean the sieve in the water connection
regularly.
ATTENTION
The sieve must not be damaged.
Remove coupling from the water con-
nection.
Illustration
Pull the sieve out using flat pliers.
Clean the sieve under running water.
Reinsert the sieve into the water con-
nection.
Care
Troubleshooting
You can rectify minor faults yourself with
the help of the following overview.
If in doubt, please consult the authorized
customer service.
DANGER
Risk of electric shock.
Prior to all work on the appliance,
switch off the appliance and pull the
power plug.
Appliance is not running
Pull on the lever of the trigger gun; the
device will switch on.
Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the mains supply.
Check the mains connection cable for
damages.
Pressure does not build up in the
appliance
Appliance ventilation: Switch the appli-
ance on with the high-pressure hose
detached and operate (max. 2 minutes)
until the water exits the high-pressure
connection without bubbles. Switch off
appliance and reconnect high-pressure
hose.
Check the water supply.
Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.
Strong pressure fluctuations
Clean high-pressure nozzle: Remove
dirt and debris from the nozzle bore, us-
ing a needle and rinse through with wa-
ter from the front.
Check water flow quantity.
Appliance is leaking
Slight leakage from the appliance pump
is normal. If the leakage increases con-
tact the authorized customer service.