Troubleshooting - Franklin Electric ESP50AM Manual De Instrucciones

Ocultar thumbs Ver también para ESP50AM:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
Automatic Models
The pump operation is designed to be completely au-
tomatic, the integral switch (if so equipped) is preset at
the factory to turn the pump on and off when the fl uid
level in the tank reaches a specifi c height. Separate
AIR LOCKING
If the pump is placed into the water while running, it will
air lock. This means that air is trapped in the pump,
preventing it from pumping water. To avoid this, always
MAINTENANCE
Your pump has been built to give many years of
satisfactory service. No regular maintenance is
required since the pump is completely self lubricating.
The following routine checking procedure is
recommended once a year and is especially important
for occasional-use applications.
SAFETY TIPS (ELECTRICAL)
1) Never make adjustments with the power connected.
Always disconnect your pump from the electrical outlet
before beginning any service procedures.
2) Do not stand on wet fl oor when servicing.
SYMPTOM
Motor does not run
Motor hums but with reduced fl ow or none
at all
Runs continuously
CAUTION
A plugged pump inlet can be mistaken for a faulty switch.
If the pump runs continuously or for extended periods be-
tween turn offs - First check for a partially plugged inlet.
"piggyback" style switches must be carefully adjusted
during installation to ensure proper operation.
Manual Models
Plug in and unplug the electrical cord as required or
use a certifi ed control for starting and stopping, of equal
or greater horsepower rating than the pump.
place the pump in the water when it is off, and then
plug it in. If the pump does air lock, simply unplug it
and then plug it back in.
a) Check the power cords and electrical outlet for
b) Ensure there is no build-up of sludge or sediment
c) Manually fi ll the sump to check for correct switch
3) Do not put your fi nger into the fuse socket - it could be
fatal.
4) Never remove the round pin from your plug; this is the
ground and is there for your safety.

TROUBLESHOOTING

CAUSE
Blown fuse
Tripped circuit
Disconnected plug
Corroded plug
Tripped overload
Defective switch
Defective motor
Float-improper position
Impeller jammed
Plugged check valve
Partially blocked inlet
Line leak
Worn impeller
Defective motor
Plugged inlet
Defective switch
Float obstruction
Plugged check valve
3
damage or corrosion.
in the sump.
adjustment and pump operation.
REMEDY
Replace fuse
Reset
Reinstall
Clean prongs
Allow pump to cool, investigate cause (jammed impeller)
Replace switch
Replace pump/repair
Check for freedom of movement
Remove bottom plate and clean.
Remove valve, clean or replace
Clean inlet
Repair
Replace pump/repair
Replace pump/repair
Clean inlet
Replace switch
Adjust position of pump
Remove valve, clean or replace

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Esp50avEsp50mEsp33amEsp33avEsp33m

Tabla de contenido