INSTALLATION
AND SETUP
Your SmartWasher is shipped fully assembled. (The OzzyMat,
support grid and false bottom of the sink are packed inside the
sink). Visually inspect for damage (minor scratches and scuffs
are normal due to the molding process).
The SmartWasher will weigh approximately 300 pounds (136
Kg) when it is filled with fluid. It should be installed close enough
to a nominal 115 VAC (220VAC), Ground Fault Circuit
Interrupter (GFCI) electrical outlet so that it can be plugged in.
The SmartWasher should be the only item plugged in to this cir-
cuit. Do not plug in before adding fluid.
PARTS WASHER SETUP
1. Remove the false bottom and
check to make sure the mat
support grid is in the bottom
of the sink. Remove and dis-
card packing material
2. Remove the OzzyMat from its
package, unfold it and lay it
on the mat support grid (white
side up).
3. Place the false bottom in
position in the sink.
4. Form the flexible nozzle to its
desired shape and be sure that the parts brush is inside the
sink.
5. At start up, carefully add 25 gallons (five 5-gallon boxes) of
OzzyJuice to the SmartWasher by slowly pouring the solu-
tion directly into the sink.
6. Plug the unit into a 115V (220VAC) GFCI electrical outlet.
7. The SmartWasher will take approximately four hours to
heat up to its selected optimal temperature of 108° F(+-2°)
(42°C)(+-1°) OR 115° F(+-2°) (46°C)(+-1°). This tempera-
ture will be maintained as long as the SmartWasher is
plugged in and full of OzzyJuice. (If the low fluid lights are
on, the heater automatically shuts off.)
PARTS WASHER OPERATION
1. The pump on your SmartWasher can be turned on by push-
ing the knee switch (labeled "Push to Start Flow") or push-
ing on the Flow Start / Stop button. When you push the
Start / Stop button, the fluid will continue running until the
Start / Stop button is pressed again. The knee switch is
connected to a timer which automatically stops the fluid flow
after 10 or 30 minutes.
2. Adjust the valve at the base of the faucet to control the flow
of the fluid through the faucet. The valve at the base of the
brush hose controls the flow of fluid through the brush.
Both outlets can be operated independently or together.
False Bottom
White
Side UP

OzzyMat

Mat Support Grid
ChemFree Technical Support 1-800-521-7182 x2624
www.ChemFree.com
IMPORTANT MAINTENANCE NOTICE
The OzzyMat must be changed at least every 30 days or the
Ozzy microbes will lose their effectiveness!
OzzyMat – FL-3/FL-4
The OzzyMat traps sludge and dirt as
small as 50 microns. It works effective-
ly even when it appears dirty. At some
point, however, it will become saturat-
ed and unable to pass fluid freely and
must be changed. The Smart Washer
has bypass openings located under
the false bottom of the sink to accom-
modate overflow when the OzzyMat is
clogged. Upgrading to an OzzyMat
FL-4 allows you the benefit of being
able to peel layers between mat
changes.
REPLACING THE
OZZYMAT
(Must be done
every 4 weeks!)
1. Make sure the pump is not running.
2. Lift out the false bottom of the sink and lean to one side.
3. Remove the soiled OzzyMat.
4. Remove a new OzzyMat from its poly bag, unfold it and lay
it on top of the support grid with the white side up.
5. Wring excess fluid on to new OzzyMat. It is important to
WRING used OZZYMAT prior to disposal.
6. Place used OzzyMat into the poly bag the new mat came in.
7. Replace false bottom in sink.
8. Discard OzzyMat in accordance with local regulations.
CHECK LOCAL REGULATIONS
You may be able to dispose of your used OzzyMat as solid
waste or with your other absorbent mats.