SMR
7.1.Manual Defrosting
Aside from automatic defrosting, it is possible to activate manual defrosting when
the temperature conditions exist by pressing the key for 5 seconds.
7.2.Adjust Clock
Go into Parameters:
•
Press the key for 3 seconds.
•
Introduce the corresponding password: "22".
•
Confirm by pressing the key.
Navigate through the corresponding parameters by pressing the keys
and modify according to the following table.
Parameters for
modification
Tc-y
Tc-m
Tc-d
Tc-u
Tc-h
Tc-n
NOTES:
•
After modifying all the parameters, record them by pressing down the key
continuously until the temperature appears.
•
During new installation, adjust the clock; otherwise, it may defrost outside of
the time determined. Also adjust the time for turning the light on/off.
Meaning
Current year
Current month
Current day of the month
Current day of the week
Current hour
Current minute
33
English
and/or
Action
Validate with
key