FRICON SMR Serie Uso Y Mantenimiento página 39

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
SMR
Very Noisy Equipment
• Check if the appliance is placed on an even surface.
• Check if vents are unobstructed.
• Check if the screws and nuts are perfectly secure.
• Check if the cooling fan has any problems/does not operate properly.
• Check if the compressor has any problems/does not operate properly.
• Check if any of the condenser's support parts are loose/broken.
Lighting Does Not Operate
• Check if lighting has power.
• Check if lighting was turned off by timer (Carel Control Panel).
Lots of Ice on Equipment Walls
• Check if the AD equipment executes automatic defrosting.
• Check if the lid's sealing is correct.
• Check if the products are touching the interior walls.
• Check if the defrost gutter resistance is damaged.
• Check if the local temperature and relative humidity conditions exceed the
equipment's climate classification (found on the characteristics label).
High Electric Energy Consumption
• Check if the set point is at maximum.
• Check if the condenser is blocked.
• Check if the lids are properly closed.
• Check if the local conditions exceed the equipment's climate classification
(found on the characteristics label).
• Check the equipment's ventilation channels (correct distance between
objects or if cooling fan motor is operating).
Condensation in Equipment
• Check if the set point is at maximum.
• Check if the products are over the load limit.
• Check if the glass is dirty or obstructed with adhesives.
38
English

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido