Kohler K-1652 Guia De Instalacion página 13

Ocultar thumbs Ver también para K-1652:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting Guide (cont.)
Symptoms
4. "Err 4" appears on the control
pad.
5. "Err 5" appears on the control
pad.
"Err 6" appears on the control
6.
pad.
7. "Err 7" appears on the control
pad.
8. "Err 8" appears on the control
pad.
9. Unit shuts off.
10. No steam is being generated.
11. There is a continuous flow of
water from the steam head.
(Water flow during automatic
purge cycle is normal.)
Kohler Co.
Probable Causes
A. "Time" button is stuck.
A. Maximum heat has been
exceeded. The generator is not
getting enough water.
B. Water feed assembly is
blocked.
A. Indicates float switch tripped
for 10 seconds.
A. "Temperature" button is stuck.
A. "Clock" button is stuck.
A. Unit has been in operation for
more than 20 minutes.
A. Piping not properly attached.
B. Steam head blocked.
A. Water supply incorrectly
attached to steam generator.
B. Water feed assembly is stuck.
13
Recommended Action
A. Reset the power at the breaker.
A. Check the water supply for
proper flow.
B. Remove and inspect the water
feed assembly in the generator.
A. Shut off the system and allow
it to cool.
A. Reset the power at the breaker.
A. Reset the power at the breaker.
A. Turn unit back on.
A. Reattach the pipes properly.
B. Remove the steam head (after
cooling) and check that the
plunger slides freely in the cap.
A. Connect the water supply to
the proper inlet.
B. Remove and inspect the water
feed assembly in the generator.