Power supply
Fig. 16
4. Connect the power supply cable (10-30 VDC)
to a free switch for the on-board electronic
devices (min. 5A): connect the positive terminal
to the red cable and the negative terminal to the
black cable. The power supply line must have
cables with a minimum cross section of
2
2.5 mm
with a length up to 4 m, of 4 mm
longer cables.
Fig. 17
www.glomex.it
Backside of the power
supply
From the antenna
Red
Black
2
for
VENUS SATURN MARS RHINE
Backside of the control unit
To the decoder (V9000-V9100-V9801)
To the multiswitch (V9104-V9804) HH
To the multiswitch (R9804) VL
10 ÷ 30 VDC
S
WARNING
Do not use power supply from secondary circuits.
This could jeopardize the operation of the equip-
ment.
S
WARNING
In order to prevent that current leakage or charge
build-up may damage the electronic components of
the antenna, make sure there is an efficient
grounding system.
S
WARNING
Pay attention not to bend the coaxial cables at a
right angle; the bending angle must always be
higher than 120°.
NOTE (applies to V9000): in case a cable longer
than 10 m should be necessary for connecting the
control unit to the satellite receiver, we recommend
installing line amplifier V9115 between them.