SFA SANI BEST Pro Manual De Instalación página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
The boxed numbers (e.g.
) refer to the explanatory diagrams and the circled numbers (e.g. 7a ) refer to the scatter diagram on the last page.
1
Warning: Ensure the electricity is turned OFF at the main
switch board before wiring to connector.
All work on cable and motor should only be carried out by a
qualified Saniflo servicing agent, as special tools are requi-
red.
8
NORM
• SANIBEST Pro
conforms to the European directives and
®
standards on electrical safety, electromagnetic compatibility
and building products. It conforms to EN 12050-3 (lifting
plant for wastewater containing faecal matter for limited
applications).
9
COMMISSIONING THE UNIT
Once electrical and plumbing connections have been made,
flush the WC once. The motor should run from 5 to
10 seconds to clear the waste (depending on the length and
height of the pipe run). If it runs for more than 30 seconds,
check that the discharge pipe is not kinked or blocked or
check that the non-return valve is correctly installed.
Flush the WC checking that all seals, and connections are
watertight. Check both the discharge pipework from the
unit, and the waste pipes from washbasin or shower.
WARNING:
There should be no dripping of water from the
WC cistern or taps. If there is, this will cause the unit to
activate repeatedly as it pumps the water away.
10
USAGE
A WC fitted with a SANIBEST Pro
not require any special maintenance.
The SANIBEST Pro
will operate automatically as soon as
®
the required level of water enters the case.
WARNING:
The water authorities strongly discourage the
disposal of sanitary items such as condoms, tampons and
sanitary pads via a WC. Nowever, should such items be
flushed down a WC attached to SANIBEST Pro
able to accept these items without blocking.
However, any such use lies outside the field of application,
and any damage caused to the unit due to maceration of these
foreign bodies, together with wipes, food products, hairs,
objects made of metal, wood or plastic, or solvents, acids and
other chemicals, lies outside the scope of the
guarantee.
11
CARE OF YOUR SANIBEST
In order to remove scale and clean the macerator and the
bowl, use a household descalent.
• Disconnect the macerator power,
• Pour an amount of descalent in the pan
• leave it to stand for 1 or 2 hours,
• Re-connect the macerator power,
• Rinse by operating the flushing system twice.
Carry out the operation once every 3 months on average, but
the frequency may need to be changed depending on the
hardness of the water.
FAULT FINDING/REMEDIES
12
For the most part any inconsistencies in the operation
of the unit will be minor and easily rectified. Please refer
to the chart below. If the problem cannot be easily remedied
in this way. Please call our Service organisation.
8710 127 SANIBEST PRO NOTICE-exe.indd 9
pump/macerator does
®
, the unit is
®
®
UNIT
9
Warning - Always disconnect the electricity supply before
attempting any work on the SANIBEST Pro
SYMPTOM
PROBABLES CAUSES
• The motor intermittently
• The WC cistern or taps are
activates
dripping
• The external non-return
valve is faulty
• Motor is surging and water
• The air opening 26 of the
in the WC pan goes down
unit is blocked
very slowly
• The motor operates
• The length or height of the
normally, but continues to
installation is over the
run for a long time
specification, or there are
too many bends/elbows
• The unit is blocked
• The motor does not
• The electrical supply is not
activate
active
• Problem with motor or
electrical chamber
• The motor hums, but does
• The capacitor 38 or motor
not run
is defective
REMOVAL
13
All work involving dismantling of the appliance must be
carried out by an approved repair agent
Any replacement of the power supply cable should only be
carried out by an authorised SANIFLO service engineer.
CHANGING THE CONDENSER, MINIATURE CIRCUIT BREAKER, MEMBRANE OR
ELECTRONIC CARD.
If positioning allows, this intervention can be made without taking apart
the large lid.
Unplug the machine
A
Unscrew the side hood 2c . You will be able to access the conden-
B
ser, miniature circuit and electronic card.
To change the membrane, disconnect the engine wires from the
C
electronic card. Then remove the pressure gauge (quarter turn).
Note! To put a new membrane in place, it is necessary to
have a special collar (to set firmly).
REMOVING THE UNIT
Disconnect the electricity supply
D
Turn off the water feed to the WC cistern. Bail out as much water
E
from the cistern as possible.
a) Remove the outlet elbow 21d
F
b) Disconnect the engine wires from the electronic card.
Remove the watertight microband 55 .
c) Unclip and lift the cover and disconnect the linking sheath from
the pressure gauge 54 and 55 .
d) Lift out the motor
The hood may be hot – do not touch!
WARNING :
Do not activate the motor when 'dry'.
(otherwise support washers will be irreparably destroyed)
REMOVAL OF BLADES
Unscrew the 3 blade screws 12 .
G
Repair or exchange the blade assembly 5 .
H
RE-ASSEMBLY OF THE BLADES
Before re-assembly, ensure that the drive coupling
I
well pressed into the base of the pump
NOTE:
For easy replacement of the lid, lubricate the lid seal 2b
with liquid soap.
Do not reconnect the electrical power supply
until t he re-installation is complete.
14
GUARANTEE
SANIBEST Pro
is guaranteed for 2 years, subject to
®
correct installation and usage.
®
REMEDIES
• Check the appropriate
washers / seals on the
cistern / taps etc
• Clean or replace the
non-return valve
• Clean the air vent
• Check the installation
• Call a service engineer to
inspect the motor
• Restore the electrical
supply
• Call a service engineer to
inspect the motor
• Call a service engineer to
inspect the motor
is
4
.
11
14/09/10 17:07

Publicidad

Tabla de contenido
loading

Tabla de contenido