•
Do not insert any tool or foreign objects into
the valve outlet or safety relief valve. You
may damage
the valve and cause a leak.
Leaking propane
may result in explosion,
fire
severe personal injury, or death.
•
If a leak is detected
at any time, STOP and
call the fire department.
•
If you cannot stop a gas leak, immediately
close the LP tank valve and call a LP gas
suaalier or your fire deaartment!
•
Never attempt
to attach this grill to the self-
contained
LP gas system of a camper trailer
or motor home or to any unregulated
source
of propane.
•
Do not use this grill until leak tested.
Leak Testing
Valves,
Hose, and Regulator
1.
Turn all grill control knobs to OFF.
2.
Be sure regulator
is tightly
connected
to LP tank.
3.
Completely
open LP tank valve by slowing turning
the
OPD hand wheel counterclockwise.
If you hear a
rushing sound, turn gas off immediately.
There is a
major leak at the connection.
Correct before
proceeding
by calling for replacement
parts at 1-
800-4-MY-HOME®.
4.
Brush soapy solution onto the areas indicated by
arrows in the figure below.
For Safe Use of Your Grill and to Avoid Serious
Injury:
•
Do not let children
operate
or play near your grill.
Keep pets away from your grill.
•
Keep grill area clear and free from materials
that
burn.
•
Do not block holes in sides or back of grill.
•
Check burner flames
regularly.
•
Use grill only in well-ventilated
space. NEVER use
in an enclosed space such as a carport,
garage,
porch, covered
patio,
or under an overhead
structure
of any kind.
•
Do not use charcoal
or ceramic
briquets
in this
gas grill.
•
Use grill at least 36 inches (914mm) from any wall
or surface.
Maintain
10 ft. clearance
to objects
that can catch fire, or sources of ignition
such as
pilot lights on water
heaters, live electrical
appliances,
etc.
•
NEVER attempt
to light burner with lid closed. A
buildup
of non-ignited
gas inside a closed grill is
hazardous.
•
Never operate
grill with LP cylinder
out of correct
position
specified
in assembly
instructions.
•
Always
close LP cylinder
valve and remove
coupling
nut before moving
LP cylinder
from
specified
operation
position.
5.
If "growing"
bubbles
appear,
there is a leak. Close
LP tank valve immediately
and retighten
connections.
If leaks cannot be stopped do not try to repair. Call
Sears for replacement
parts at 1-800-4-MY-HOME®.
6.
Always
close LP tank valve after
performing
leak test
by turning
hand wheel clockwise.
Apartment
and Condominium
Dwellers
Check with management
to learn the requirements
and
fire codes for using an LP gas grill in your complex.
If
allowed,
use outside on the ground
floor with a three (3)
foot clearance
from walls or rails. Do not use on or under
balconies.