INIM Electronics Air2 Manual De Instalación Y Programación página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Enroll the terminal by selecting the type.
Double-clicking on the configured terminal will open a window where you can
program the zone. The lower part of the window shows the "Wireless section",
right-click and select the "Wireless" option. Select the type of device, in the "Type"
field, then start the guided enrolling process by clicking-on the "Enroll" button.
Air2 device
IR100
Reed contact
Terminal "T1"
MC300
Terminal "T2"
FD100
XIR200W
OTT100W
ODI100W
UT100
MC200
Curtain detector
DT200T
Detector direction
XDT200W
4.
For Air2 devices press the ENROLL button.
5.
If you are enrolling an output device that is connected to a terminal of any
device with an Air2-MC300 output terminal, you must enable the "Broad-
cast RF" zone option.
Once done, you must step back to the configuration of the terminal and
configure it as an "OUTPUT".
The "Broadcast RF" option must be enabled for each terminal of the Air2-MC300
device concerned.
6.
Enroll all remote controls in the same way as you would enroll keys, and
select as the reader the one with the same address as the expansion.
7.
Set the parameters of the zones, outputs and keypads.
After changing the battery, it is advisable to press the ENROLL button in order to
be sure that the device is synchronized with the wireless transceiver.
If you are installing Air2-MC300 devices in the system together with Air2-MC100
(no longer in production), distinction of the type of device may be possible for any
control panel under the following conditions:
The Air2-BS200 firmware version must be 5.00 or higher
The SmartLeague software version must be 3.5.1.5 or higher
The Prime/STUDIO software version must be 1.00 or higher
If you are using an Air2-BS100 transceiver, distinction between Air2-MC300 and
Air2-MC100 is impossible.
16
Table 19: Wireless terminal types
Single/Double
Single
Single
Terminal 1 Magnetic
Single
Terminal 2 Magnetic
Single
Single
Single
Single
Single
Single
Double
Double
Double
Directional detector
Double
Via software
Infrared
Infrared detectors
Magnetic contact
Magnetic Contact
Terminal T1 MC
contact
Terminal T2 MC
contact
Smoke detector
Smoke detector
Passive infrared
Single T detector
detector
Outdoor terminal
OutdoorDetector
Outdoor terminal
OutdoorDetector
Outdoor terminal
OutdoorDetector
MC200 magnetic
Cont.Magn.MC200
contact
Curtain detector
Curtain detector
Curtain direction
Dual technology
Dual T detector
detector
Wireless accessories
Via software
Via keypad
Note
CHANGING THE
BATTERY
ENROLLING THE
MC300
Installation

Publicidad

Tabla de contenido
loading

Productos relacionados para INIM Electronics Air2

Tabla de contenido